Descriptions
・AC adapter for connectable battery charger
Specifications
Input Voltage | 100 - 240 V AC |
---|---|
Output Voltage | 15 V DC |
Output Current | 4 A |
Connector Information | Φ5.5 mm (outer)/Φ2.1 mm (inner) / 9.5 mm Length |
Cable Length |
DC Output: 1200 mm; 47.2 in AC Input: 1830 mm; 72.0 in |
Note | Information for (EU)2019/1782 is avilable in "Support / Download". |
IDAS Radios
IP Radios
Wi-Fi Radios
When uniting 2 or more chargers
-
- BC-257
- MULTI-CONNECTABLE CHARGER STAND
-
- BC-228
- AC ADAPTER
* BC-228 is necessary for 2 to 4 BC-257s connected.
When uniting 2 or more chargers
-
- CHARGER ADAPTER
-
- BC-228
- AC ADAPTER
-
- BC-202IP3L
- MULTI-CONNECTABLE DESKTOP CHARGER
* BC-228 is necessary for 2 to 6 BC-202IP3Ls connected.
When uniting 2 or more chargers
-
- CHARGER ADAPTER
-
- BC-228
- AC ADAPTER
-
- BC-226
- DESKTOP CHARGER
* BC-228 is necessary for 2 to 6 BC-226s connected.
When using one charger
-
- BC-123S (Straight plug type)
- AC ADAPTER
-
- BC-228
- AC ADAPTER
-
- CP-25H
- CIGARETTE LIGHTER CABLE
-
- BC-202IP3L
- MULTI-CONNECTABLE DESKTOP CHARGER
* Use straight plug version for the BC-123S.
When using one charger
-
- BC-123S (Straight plug type)
- AC ADAPTER
-
- BC-228
- AC ADAPTER
-
- BC-226
- DESKTOP CHARGER
* Use straight plug version for the BC-123S.


Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |