IP Transceiver
IP503HLite
You Can Talk and Listen at the Same Time
Full-Duplex, Dual SIM IP Radio
Instant Wide Area Coverage Over an LTE/3G Network
It provides wide area communication using a cellular network.*
* Network coverage provided by a generally available data SIM card. Radio registration is required separately.
Simultaneous TalkListen Function for Full-Duplex Communication
Dual SIM Capability for Communication Redundancy
Two different SIM cards can be installed. Switch between them as required.*
* Single standby only
Multiple User Communication
Multiple users in the call groups can initiate calls instantaneously.
Priority Interrupt Calling
You can break into an on-going call to transmit an important message.
Industry Leading Compact and Lightweight Design
IP67 Dust-Tight and Waterproof
900 mW Powerful and Clear Audio
Other Features
- Individual, Group, Talkgroup, Multiplex Talkgroup and All calls*1
- Emergency button, Lone Worker and Man Down functions
- Vibration alert function notifies of incoming call
- Up to 500 memory address book(including Group, Individual, Talkgroup and Telephone lists)
- Voice message recording
- Built-in Bluetooth®*2. capability and GPS
*1 Depending on system configuration *2 Version without Bluetooth also available. Ask your Dealer for details.
VE-SP1, Just Slot in the IP503H Lite and Start a Voice Conference
Case Studies
Note for IP503H users
The IP503H Lite(front panel is blue) uses a generally available data SIM card and is controlled by the IP4000C system.
The IP503H Lite is not compatible with IP503H radios (black front panel) which use a closed network provided by custom Icom SIM card.
Bluetooth® connection has not been tested for all Bluetooth® compatible devices with this product. This does not guarantee that all devices will work with this product.
Network | EXP |
LTE B1, B3, B7, B8, B20 |
---|---|---|
AUS | LTE B1, B3, B5, B7, B8, B28 W-CDMA B1, B5 |
|
Dimensions (W × H × D; Projections not included) |
59 × 95 × 32 mm; 2.3 × 3.7 × 1.3 in (with BP-272) |
|
Weight (approx.) | 240 g; 8.5 oz (with BP-272 and antenna) |
|
Voice Codec |
G.726 (32 kbps) |
|
AF output power (8 Ω at 10% distortion) |
Internal SP | More than 900 mW |
External SP | More than 200 mW | |
Operating time*1 (TX : RX : standby = 5 : 5 : 90) |
More than 17 hours (with BP-272) | |
Bluetooth*2 | Ver 2.1 +EDR | |
GPS | Built-in | |
Operating temperature | –10 °C to +60 °C; +14 °F to +140 °F | |
IP rating |
IP67 (dust-tight and waterproof) |
*1 Operating time may differ depending on operating environments. *2 Version without Bluetooth also available. Ask your Dealer for details.
All stated specifications are subject to change without notice or obligation.
Applicable U.S. Military Specifications
Standard |
|
|
---|---|---|
|
|
|
Low Pressure | 500.5 | I, II |
High Temperature | 501.5 | I, II |
Low Temperature | 502.5 | I, II |
Temperature Shock | 503.5 | I-C |
Solar Radiation | 505.5 | I |
Rain Blowing/Drip | 506.5 | I, III |
Dust Blowing | 510.5 | I |
Immersion | 512.5 | I |
Vibration | 514.6 | I |
Shock | 516.6 | I, IV |
Also meets equivalent MIL-STD-810 -C, -D, -E and -F.
Supplied Accessories
- BP-272 Li-ion battery pack
- MB-135 belt clip
- Hand strap
- Antenna
MICROPHONES
HEADSETS
PTT/VOX CABLES
CHARGERS
AC ADAPTERS
POWER SUPPLY CABLES
MOUNTING BRACKETS
BELT CLIPS
SHOULDER STRAP
CARRYING CASES
ADAPTER CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
IP503H Lite | 1.15MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
INSTRUCTION MANUAL | IP503H Lite | |
INSTRUCTIONS | IP503H Lite |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |