COMMANDMIC
HM-195GW
- Rating of waterproofing is equivalent to the rating of the radio it is connected to.
Descriptions
・Full remote-control capability for Icom marine transceivers
・New Intuitive User Interface
・Submersible (1 m depth for 30 min.)
・Intercom function with compatible Icom marine transceivers
・Up to 18.3 m (60.3 ft) remote location installation*
* Two optional OPC-1541 extension cables required.
・DSC “Distress” button on back of unit
・Supplied Accessories
- 6.1 m (20 ft) of cable
- Mounting base for cable connector
- Microphone hanger
Specifications
Operating Temperature Range | -20℃~+60℃ |
---|---|
Audio Power Output | 2.0 W typ. @ 10% distortion with 4 Ω |
Waterproof | IPX7 |
Cable Length | 560 mm; 22.0 in (when curled) |
Note | Super white color |
Marine VHF
CONNECTION CABLE + EXTENSION CABLE
-
- OPC-2384
- CONNECTION CABLE
-
- OPC-1541
- EXTENSION CABLE
-
- HM-195GB
- COMMANDMIC
-
- HM-195GW
- COMMANDMIC
OPC-2384 is a required accessary to connect the IC-M605/EURO and the HM-195B/GW.
Up to two extension cables, OPC-1541 available.
EXTENSION CABLE
-
- OPC-1541
- EXTENSION CABLE
-
- HM-195B
- COMMANDMIC
-
- HM-195GB
- COMMANDMIC
-
- HM-195GW
- COMMANDMIC
-
- HM-195SW
- COMMANDMIC
Up to two OPC-1541 cables available.
L-Type CONVERSION CABLE
-
- OPC-2523L
- CONVERSION CABLE
-
- HM-195B
- COMMANDMIC
-
- HM-195GB
- COMMANDMIC
-
- HM-195GW
- COMMANDMIC
-
- HM-195SW
- COMMANDMIC
OPC-2523L is a L-type conversion cable for the HM-195 series (10-pin connector).
Catalogs / Brochures
Brochures Name | Size |
---|---|
Marine Products | 6.48MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Instructions | HM-195 |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |