Descriptions
・Switching AC-DC converter with some versions to meet to each AC plug
Specifications
Input Voltage | 100 - 240 V AC |
---|---|
Output Voltage | 12.0 V DC |
Output Current | 330 mA |
Connector Information | Φ5.5 mm (outer)/Φ2.1 mm (inner) / 9.5 mm Length |
Cable Length | 1830 mm; 72.0 in |
Note | Information for (EU)2019/1782 is available in "Support / Download". |
MICROPHONE CONNECTION
-
- HM-152
- HAND MICROPHONE
-
- SM-26
- DESKTOP MICROPHONE
-
- CT-23
- PTT MICROPHONE ADAPTOR
-
- BC-147S
- AC ADAPTER
POWER SUPPLY
-
- BC-147S
- AC ADAPTER
-
- BC-206SE
- AC ADAPTER
-
- CP-23L
- CIGARETTE LIGHTER CABLE
-
- OPC-515L
- DC POWER CABLE
-
- BC-192
- DESKTOP CHARGER
BC-147SA or BC-206SE may be supplied with the BC-192 depending on versions (Refer to BC-192 page for detail)
POWER SUPPLY
-
- BC-147S
- AC ADAPTER
-
- CP-23L
- CIGARETTE LIGHTER CABLE
-
- OPC-515L
- DC POWER CABLE
-
- BC-152N
- DESKTOP CHARGER
POWER SUPPLY
-
Discontinued product
- BC-171
- DESKTOP CHARGER
-
- BC-147S
- AC ADAPTER
-
- OPC-515L
- DC POWER CABLE
BC-147S may be supplied with the BC-171 depending on the versions. (Refer to BC-171 page for details)
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Information for (EU)2019/1782 | BC-242/AD-55NS/SP-39AD/BC-228/BC-157S/BC-207S/BC-258E/BC-123SE/BC-123SUK/BC-167SD/BC-236/BC-147SE/BC-217SE/BC-145SE/BC-145SUK/BC-206SE/BC-196SD/BC-267E |



Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |