The ID-RP2010V/RP4010V/RP1200VD is a 144/430 (440)/1200 MHz D-STAR repeater compatible with the D-STAR mode as well as analog FM for mixed mode operation. With an internal controller, the RF modules can function as a single band D-STAR/FM repeater. (ID-RP2C Controller is not required.)
For repeater owners with limited Internet resources, the optional UX-262 LTE Unit provides wireless Internet access. Combine the LTE unit and the Internet Gateway function, you can drop a repeater anywhere with LTE connectivity and be on the global network.
Integrated Controller Function
Compatible with Repeater Controller, ID-RP2C
These new D-STAR repeaters are also compatible with the external repeater controller, ID-RP2C. You can replace a repeater module in an existing ID-RP2 series D-STAR repeater site to use with the ID-RP2C repeater controller.
DD Mode Operation (ID-RP1200VD only)
The 1.2 GHz repeater, ID-RP1200VD works in either DV or DD mode (switchable). DD mode provides data communication and Internet access at 128 kbps. The IC-9700, which has 1.2 GHz DD mode, becomes your wireless modem through your computer’s Ethernet port.
Optional LTE Unit, UX-262 for Wireless Internet Connection
By installing the optional LTE unit, the repeater can be directly connected to an LTE network* and the Internet. When using multiple repeater modules in a site, one LTE network can be shared with the multiple repeater modules. (up to 4 modules)
* Network coverage provided by a generally available data SIM card. A static Global IP address is required for the Internet SIM.
Simple Internal Gateway Function
In combination with the optional LTE unit and simple internal Gateway function, a provisional D-STAR repeater site* can be easily deployed in the field in an emergency situation.
* Please check the legal requirements in your country before using the provisional repeater site.
D-STAR DV/Analog FM Mix Mode Operation
When using the Mix mode operation, the repeater receives both D-STAR DV and analog FM mode signals and relays the received signal in the same mode. This Mix mode function is convenient for migrating an existing analog repeater to an D-STAR repeater, while keeping analog FM mode compatibility. Single mode operation (either DV or FM mode) is also programmable. For analog FM mode operation, CTCSS, DTCS codes and 1750 Hz tone are programmable.
* The D-STAR gateway function cannot be used with FM mode signal.
The Mix mode operation is not available with the ID-RP2C repeater controller.
High Duty Cycle Operation
Employing a high-performance power amplifier, the D-STAR repeater can endure up to 60 minutes of continuous transmission and provides a reliable high duty cycle operation at 25 W RF output*.
* 25 W RF output power for ID-RP2010V/ID-RP4010V. 10 W output for ID-RP1200VD
New RF Direct Sampling and FPGA Platform
The ID-RP2010V/RP4010V repeaters use the RF Direct Sampling method. For 1.2 GHz, the Down Conversion IF sampling is used in the ID-RP1200VD repeater. Signals are processed in the FPGA digital domain, that eliminated distortion and other elements seen in the legacy superheterodyne receivers. The result is receiver sensitivity that is greatly improved.
Other Features
- 19-inch rack mount 2U height low profile
- CW ID/Voice ID transmitter
- SD card slot for firmware update, saving setting data and FM mode Voice ID audio
- 10 MHz reference signal input
D-STAR System Overview
FRONT PANEL VIEW (Photo shows ID-RP2010V)
REAR PANEL VIEW (Photo shows ID-RP2010V)
GENERAL
ID-RP2010V | ID-RP4010V | ID-RP1200VD | ||
---|---|---|---|---|
Frequency range (USA version) | TX/RX: 144–148 MHz | TX/RX: 440–450 MHz | TX/RX: 1240–1300 MHz | |
Type of emission | F3E, F7W, F2A (ID transmission) |
F3E, F7W, F2A (ID transmission) |
F3E, F1D, F7W, F2A (ID transmission) |
|
Frequency stability | ±0.5 ppm or less (–10 °C to +50 °C) | ±0.5 ppm or less (–10 °C to +50 °C) | ±0.5 ppm or less (–10 °C to +50 °C) | |
Transfer rate | DV: 4.8 kbps | DV: 4.8 kbps | DV: 4.8 kbps, DD: 128 kbps | |
Antenna impedance | 50 Ω | 50 Ω | 50 Ω | |
Power supply requirement | 13.8 V DC ±15 % | 13.8 V DC ±15 % | 13.8 V DC ±15 % | |
Current drain (approximate) |
TX | Less than 9.0 A (High), 4.0 A (Low) | Less than 7.0 A (High), 3.0 A (Low) | Less than 5.0 A (High), 3.0 A (Low) |
RX (Max. AF power) |
Less than 1.8 A | Less than 1.8 A | Less than 1.8 A | |
Operating temperature range | –10 °C to +50 °C, –14 °F to +122 °F | –10 °C to +50 °C, –14 °F to +122 °F | –10 °C to +50 °C, –14 °F to +122 °F | |
Dimensions (Projections not included, W × H × D) |
482 × 88 × 275 mm, 19.0 × 3.5 × 10.8 in | 482 × 88 × 275 mm, 19.0 × 3.5 × 10.8 in | 482 × 88 × 275 mm, 19.0 × 3.5 × 10.8 in | |
Weight (approximate) | 6 kg, 13.2 lb | 6 kg, 13.2 lb | 6 kg, 13.2 lb |
TRANSMITTER
ID-RP2010V | ID-RP4010V | ID-RP1200VD | ||
---|---|---|---|---|
Output power (High, Low) | 25 W, 2.5 W | 25 W, 2.5 W | 10 W, 1 W | |
Modulation system | DV/DD | Digital GMSK modulation (DV only) | Digital GMSK modulation (DV only) | Digital GMSK modulation |
FM | Digital Reactance modulation | Digital Reactance modulation | Digital Reactance modulation | |
Occupied bandwidth | DV | Less than 6 kHz | Less than 6 kHz | Less than 6 kHz |
DD | – | – | Less than 150 kHz | |
Maximum frequency deviation | ±5.0 kHz/±2.5 kHz (FM, Wide/Narrow) | ±5.0 kHz/±2.5 kHz (FM, Wide/Narrow) | ±5.0 kHz/±2.5 kHz (FM, Wide/Narrow) | |
Spurious emissions | Less than –63 dB | Less than –61.8 dB | Less than –53 dB | |
Unwanted emissions | Less than –60 dB | Less than –60 dB | Less than –50 dB |
RECEIVER
ID-RP2010V | ID-RP4010V | ID-RP1200VD | ||
---|---|---|---|---|
Receiver system | RF Direct Sampling | RF Direct Sampling | Down Conversion IF Sampling | |
Intermediate frequencies | – | – | 311 – 371 MHz | |
Sensitivity | DV (1% BER, PN9) | Less than –13 dBμV (0.22 μV) | Less than –13 dBμV (0.22 μV) | Less than –13 dBμV (0.22 μV) |
DD (1% BER, PN9) | – | – | Less than 4 dBμV (1.59 μV) | |
FM (12 dB SINAD) | Less than –15 dBμV (0.18 μV) | Less than –15 dBμV (0.18 μV) | Less than –15 dBμV (0.18 μV) | |
Selectivity | DV (12.5 kHz spacing) | Less than –50 dB | Less than –50 dB | Less than –40 dB |
DD (300 kHz spacing) | – | – | Less than –40 dB | |
FM (15 kHz bandwidth) | More than 12 kHz/–6 dB Less than 20 kHz/–60 dB |
More than 12 kHz/–6 dB Less than 20 kHz/–60 dB |
More than 12 kHz/–6 dB Less than 20 kHz/–60 dB |
|
Intermodulation rejection |
DV (20 kHz spacing) | Less than –60 dB | Less than –60 dB | Less than –50 dB |
DD (300 kHz spacing) | – | – | Less than –50 dB | |
FM | Less than –60 dB | Less than –60 dB | Less than –50 dB | |
Receive spurious | Less than 2 nW (–57 dBm) | Less than 2 nW (–57 dBm) | Less than 2 nW (–57 dBm) | |
Spurious and image rejection | More than 55 dB | More than 55 dB | More than 50 dB | |
Audio output power | More than 2.0 W (at 10% distortion with 8 Ω load) |
More than 2.0 W (at 10% distortion with 8 Ω load) |
More than 2.0 W (at 10% distortion with 8 Ω load) |
All stated specifications are subject to change without notice or obligation.
Supplied accessories
- DC power cable (3 m, 9.8 ft)
- Ethernet cable (0.6 m, 2.0 ft)
- USB cable (1 m, 3.2 ft)
- Fuses
- Rubber stands
- Allen wrench
INTERNAL UNITS
Catalogs / Brochures
Brochures Name | Size |
---|---|
D-STAR Digital Repeaters | 2.24MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
DOC (DECLARATION OF CONFORMITY) | ID-RP1200VD | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) | ID-RP1200VD | |
DOC (DECLARATION OF CONFORMITY) | ID-RP2010V | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) | ID-RP2010V | |
INSTRUCTION MANUAL | ID-RP2010V/ID-RP4010V/ID-RP1200VD | |
INSTURCTION MANUAL (German/Spanish/French/Italian) | ID-RP2010V/ID-RP4010V/ID-RP1200VD | |
SETTING GUIDE | ID-RP2010V/ID-RP4010V/ID-RP1200VD | |
DOC (DECLARATION OF CONFORMITY) | ID-RP4010V | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) | ID-RP4010V |
Firmware / Software
Type | Model Name | Version | Last Update |
---|---|---|---|
Firmware | ID-RP2010V/ID-RP4010V/ID-RP1200VD | Version 1.20 | 2024.04.09 |
USB driver | ID-RP2010V/ID-RP4010V/ID-RP1200VD | Version 1.30 | 2021.08.06 |
Firmware | ID-RP2010VID-RP4010V/ID-RP1200VD | Version 1.22 | 2024.10.18 |
Programming software | Utility for ID-RP3 | Version 1.06 | 2024.02.07 |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |