750 mW loud audio
The IC-V80/E uses the BTL (bridge-tied load) amplifier that doubles the audio output. The 36 mm large speaker delivers 750 mW of loud and intelligible audio*. Great for noisy environments.
* Typical value using with internal speaker.
Powerful 5.5 W of output power
The IC-V80/E offers a just-right mix of power and size. 5.5 watts of high power will work to get your message through. Get up to 19 hours* of operating time with the Li-ion battery pack (BP-265) or 13 hours with the Ni-MH (BP-264). All that power comes is an easy to hold and use size - not too big, not too small.
* Typical operation. 5:5:90 duty cycle with power save on.
IP54 and MIL-STD-810 rugged construction
The dust protection and water-resistance equivalent to IP54 provides reliable operation for practical outdoor operation. The IC-V80/E tested to and passed 11 categories of MIL-STD-810 environmental tests.
A total of 207 memory channels
The IC-V80/E has a total of 207 memory channels, including 200 regular channels, 6 scan edges and 1 call channel. The channel name is programmable with 5 characters for easy recognition.
Built-in CTCSS/DTCS
The CTCSS and DTCS tone codes provide quiet stand-by and allow you to use tone-access repeaters. The pocket beep alerts you when a matching tone frequency is received. The tone scan detects the subaudible tone that is used for repeater access.
Internal VOX function
The IC-V80/E has internal VOX (Voice Operated Transmit) function for convenient handsfree operation with a compatible optional headset and plug adapter cable. Also, the VOX gain and VOX delay time are adjustable.
Other features
- WX channel and weather alert function (USA version only)
- Program, memory, skip, priority and tone scans
- Power save function
- BNC type antenna connector
- Automatic repeater function (USA version only)
- 1750Hz tone for European repeater access (IC-V80E only)
- TOT (time out timer) setting
- Repeater lockout and busy channel lockout
- PC programmable with optional CS-V80
- Transceiver-to-transceiver cloning (Optional)
- Direct keypad frequency entry
- DTMF autodial memories
- Auto power off
- LCD backlight
- Wide/narrow channel spacing
General
Frequency coverage |
IC-V80 (U.S.A.) Tx: 144 - 148 MHz Rx: 136 – 174 MHz IC-V80E (Europe) Tx・Rx: 144 - 146 MHz |
||
---|---|---|---|
Current drain (approx.) |
TX High | 1.4 A (typ.) | |
RX Max. audio/Stand-by |
310 mA with Internal speaker (typ.) 180 mA with External 8 Ω speaker (typ.) 65 mA (typ.) during stand-by 20 mA (typ. 9 during Power save |
||
Dimensions (W×H×D) (Projections not included) |
52.2×111.8×22.3 mm (with BP-264) |
||
Weight |
140 g; 4.9 oz (without Battery pack) |
Transmitter
Output power (at 7.5V) |
5.5/2.5/0.5 W |
|
---|---|---|
Max. frequency deviation |
±5.0 kHz/±2.5 kHz (Wide/Narrow) |
|
Spurious emissions |
Less than -60B |
|
Ext. microphone connector |
3-conductor 2.5(d) mm (1/10″)/2.2 kΩ |
Receiver
Sensitivity |
0.14 μV typ. (at 12 dB SINAD) |
||
---|---|---|---|
Squelch sensitivity |
0.1 μV typ. (at threshold) |
||
Selectivity |
70 dB/50 dB typ. (Wide/Narrow) |
||
Intermodulation |
70 dB/65 dB typ. (Wide/Narrow) |
||
Spurious and image rejection |
75 dB (typ.) |
||
Audio output power | Internal SP |
750 mA typ. (16 Ω load) |
|
External SP |
450 mW typ. (8 Ω load) |
||
External speaker connector |
3-conductor 3.5(d)mm (1/8″)/8 Ω |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 G Method, Proc. |
---|---|
Low Pressure Storage |
500.5 I |
Low Pressure Operation |
500.5 II |
High Temperature Storage |
501.5 I |
High Temperature Operation |
501.5 II |
Low Temperature Storage |
502.5 I |
Low Temperature Operation |
502.5 II |
Temperature Shock |
503.5 I-C |
Solar Radiation |
505.5 I |
Rain Blowing |
506.5 I |
Rain Drip |
506.5 III |
Humidity Induced |
507.5 II |
Salt Fog |
509.5 |
Dust Blowing |
510.5 I |
Immersion |
512.5 I |
Vibration |
514.6 I |
Shock Functional |
516.6 I |
Shock Transit Drop |
516.6 IV |
Also meets equivalent MIL-STD-810 -C, -D, -E and -F.
Applicable IP Rating
Ingress Protection Standards | |
---|---|
Dust & Water |
IP67 (Dust-tight and waterproof protection) |
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Battery pack*
- Antenna*
- Belt clip*
- Battery charger*
- AC adapter*
* Not supplied, or the shape is different, depending on the version.
MICROPHONES
HEADSETS
PTT/VOX CABLES
CHARGERS
POWER SUPPLY CABLES
MOUNTING BRACKETS
BELT CLIPS
SOFTWARE
PROGRAMMING/DATA CABLES
CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-V80/IC-V80E(Amateur) | 363KB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Instruction Manual | IC-V80/IC-V80E/IC-U80/IC-U80E |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |