5W RF Output in 144 and 430 MHz
1500 mW Loud and Intelligible Audio
IP67 Dust-tight and Waterproof
Home Button on the Top Panel for Quick Access to Calling Channel
Optional HM-222HLWP, Loud Audio SP-MIC
FM Broadcast Receiver
Up to 11 Hours* Operating Time
* 11/10 hours (VHF/UHF, approx.) with BP-280 battery at 1:1:8 duty ratio (Power save ON)
Other Features
- DC power operation with optional AD-149H
- Free CS-T10 downloadable programming software
- Built-in CTCSS/DTCS for repeater operation
- Total of 208 memory channels with 6 character channel name
- 16 DTMF autodial memories
- Priority, Program, Memory, Skip, and Tone Scan
- Direct-conversion system eliminates IF stages
General
IC-T10 | |||
---|---|---|---|
Frequency coverage | USA Version | TX | 144–148, 430–450 MHz*1 (* Working range) |
RX | 136–174, 400–479 MHz*1 (* Working range) | ||
FM broadcast | 88–108 MHz | ||
Export Version | TX | 136–174, 400–479 MHz*2 (Working range) | |
RX | 136–174, 400–479 MHz*2 (Working range) | ||
FM broadcast | 76–108 MHz | ||
EUR Version | TX | 144–146, 430–440 MHz | |
RX | 136–174, 400–479 MHz*3 (* Working range) | ||
FM broadcast | 76–108 MHz | ||
Number of channels | 208 channels (including 2 call and 6 scan edges) | ||
Type of emission | F2D, F3E (FM) | ||
Frequency stability | ±2.5 ppm (–20°C to +60°C on the basis of 25°C ) | ||
Power supply requirement External DC power |
7.2 V DC nominal 10–16 V DC (with AD-149H) |
||
Current drain (approx.) | Tx High | Less than 2.5 A | |
Rx Max. audio | Less than 600 mA | ||
Antenna impedance | 50 Ω (SMA) | ||
Operating temperature range | –20°C to +60°C | ||
Dimensions (W × H × D, Projections not included) |
52.2 × 111.8 × 30.3 mm, 2.1 × 4.4 × 1.2 in (with BP-280) | ||
Weight (Approximate) | 278 g; 9.8 oz (with BP-280 and antenna) |
*1 Guaranteed range 144–148, 440–450 MHz
*2 Guaranteed range 144–148, 430–440 MHz
*3 Guaranteed range 144–146, 430–440 MHz
Transmitter
IC-T10 | ||
---|---|---|
Output power | 5 W, 2.5 W, 0.5 W | |
Max. frequency deviation | ±5.0 kHz/±2.5 kHz (W/N) | |
Spurious emissions |
Less than –60 dBc (High, Mid), Less than –13 dBm (Low) |
|
Ext. microphone connector | 3-conductor 2.5 (d) mm (1/10ʺ)/2.2 kΩ |
RECEIVER
IC-T10 | ||
---|---|---|
Receiver sensitivity | Less than 0.18 μV (at 12 dB SINAD) | |
Squelch sensitivity | Less than 0.18 μV (at squelch threshold) | |
Adjacent channel selectivity | More than 55 dB (FM, 25 kHz) More than 50 dB (FM Narrow, 12.5 kHz) |
|
Spurious response | More than 60 dB | |
Audio output power (at 5% distortion, 8 Ω load) |
Internal SP | 1500 mW (typical) |
External SP | 450 mW (typical) | |
HM-222HLWP | 1500 mW (typical) | |
Ext. speaker connector | 3-conductor 3.5 (d) mm (1/8ʺ)/8 Ω |
All stated specifications are subject to change without notice or obligation.
Applicable U.S. Military Specifications & IP Rating
Standard |
MIL-810 G | |
---|---|---|
Method | Procedure | |
Low Pressure | 500.5 | I, II |
High Temperature | 501.5 | I, II |
Low Temperature | 502.5 | I, II |
Temperature Shock | 503.5 | I-C |
Solar Radiation | 505.5 | I |
Rain Blowing/Drip | 506.5 | I, III |
Humidity | 507.5 | II |
Salt Fog | 509.5 | – |
Dust Blowing | 510.5 | I |
Immersion | 512.5 | I |
Vibration | 514.6 | I |
Shock | 516.6 | I, IV |
Also meets equivalent MIL-STD-810-C, -D -E and -F.
Ingress Protection Standard | |
---|---|
Dust & Water | IP67 (Dust-tight and waterproof protection) |
Supplied Accessories
- BP-280 Battery Pack
- FA-S270C Antenna
- MB-133 Belt Clip
- BC-213 Rapid Charger
- AC Adapter (BC-242 or BC-123SA/SE)
MICROPHONES
CHARGERS
POWER SUPPLY CABLES
MOUNTING BRACKETS
BELT CLIPS
PROGRAMMING/DATA CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
HAM Radios and Receivers | 6.90MB |
HAM Radios and Receivers (European Edition) | 6.98MB |
IC-T10 (A4) | 6.03MB |
IC-T10 (LT) | 6.24MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
INSTRUCTIONS | CS-T10 | |
BASIC MANUAL (English) | IC-T10 | |
DICHIARAZIONE DI CONFORMITA UE(ITALIANO) | IC-T10 | |
DOC (DECLARATION OF CONFORMITY) | IC-T10 | |
ADVANCED MANUAL | IC-T10 | |
PRECAUTIONS (French) | IC-T10 | |
BASIC MANUAL (GER/ESP/FRA/ITA) | IC-T10 |
Firmware / Software
Type | Model Name | Version | Last Update |
---|---|---|---|
Programming software | CS-T10 | Version 1.00 | 2022.03.30 |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |