VHF AND UHF DIGITAL TRANSCEIVERS
IC-F3161D
IC-F4161D
Series
LTR™/ Conventional / Digital* Multi-mode Land Mobile!
- VHF/10-keypad/IDAS DIGITAL IC-F3161DT
- VHF/Simple key/IDAS DIGITAL IC-F3161DS
- UHF/10-keypad/IDAS DIGITAL IC-F4161DT
- UHF/Simple key/IDAS DIGITAL IC-F4161DS
Basic LTR™ mode operation
Group, selective, and phone call are available in LTR™ mode.
512 memory channels with 128 zones
The 512 memory channel capacity with 128 zones allows you to divide and store a variety of channel groupings for versatile and efficient fleet management.
IDAS, 6.25kHz digital mode ready
The IDAS 6.25kHz digital mode is available with the UT-126H digital unit.*
* Already installed.
Dot matrix, multi-function LCD
The IC-F3161D series has a large dot matrix display to show information with high resolution characters. The display setting is programmable to show one line and 12 characters, or two lines and 24 characters. The bottom row shows assigned functions to the [P0] to [P3] buttons.
Voting scanning (Analog mode only)
The Voting scan detects the signal strength level of repeater sites and automatically selects the strongest station, useful for roaming between 2 or more repeater sites. Once you program for voting mode in a memory zone, you can easily start voting mode operation by changing the zone setting.
Loud audio output with BTL amp
The IC-F3161D series employs a BTL amplifier that increases the audio output and the built-in audio compander provides clear, low noise communications.
Other features
- Built-in inversion type voice scrambler
Inversion type voice scrambler is not compatible with UT-109R/UT-110R voice scrambler. - The mode independent setting automatically selects the scanning list, according to the operating channel
- Nuisance delete
- MDC 1200 compatible
- IP55 dust-protection and water jet resistance
- Optional man down unit, UT-124R and lone worker function
- Embedded ESN (Electronic serial number) and more...
General
IC-F3161DT/DS |
IC-F4161DT/DS |
|||
---|---|---|---|---|
Frequency coverage (Varies according to version) |
136–174 MHz |
400-470 MHz |
||
Number of channels |
512 ch/128 zones |
|||
Channel spacing (Varies according to version) |
12.5/25, 15/30 |
12.5/25 |
||
Type of emission |
16K0F3E, 11K0F3E, 11K0F7E/D, |
|||
Current drain | Tx High |
1.5A |
1.8A |
|
Rx | Stand-by |
150mA |
140mA |
|
Max. audio |
600mA |
|||
Dimensions (projections not included; W×H×D) |
53×136×38.9 mm; |
|||
Weight (approx.) |
340g; 12.0oz (with BP-232H) |
Transmitter
IC-F3161DT/DS |
IC-F4161DT/DS |
|
---|---|---|
RF output power |
5W |
|
Spurious emissions |
75dB (typ.) |
|
Frequency stability |
±1.0ppm |
|
Audio harmonic distortion |
3% typical |
|
FM Hum and Noise |
46dB typ. (W) |
|
Digital FSK error | 5% max. |
Receiver
IC-F3161DT/DS |
IC-F4161DT/DS |
||
---|---|---|---|
Sensitivity | FM (W, N) |
0.25μV typ. (at 12dB SINAD) |
|
Digital |
0.20μV typ. (at 5% BER) |
||
Adjacent channel selectivity (W/N) |
75/68dB (typ.) |
||
Spurious response rejection |
70dB (min.) |
||
Intermodulation rejection |
74dB (typ.) |
||
AF output power (at 5% distortion with an 8Ω load) |
500mW (typ.) |
Function Comparison and Internal Unit Options
IC-F3161DT/DS
|
||
---|---|---|
Number of option slots |
2* |
|
CTCSS/ DTCS | encoder |
Available |
decoder |
Available |
|
2-Tone | encoder |
Available |
decoder |
Available |
|
5-Tone | encoder |
Available |
decoder |
Available |
|
DTMF autodial |
Available |
|
DTMF decoder |
Available |
|
Voice Scrambler | Inversion | Available |
APCO P25 digital |
- |
|
AES encryption |
- |
|
DES encryption |
- |
|
FIPS 140-2 Level 1 |
- |
|
IDAS digital |
UT-126H** |
|
MPT 1327 |
- |
|
MDC 1200 |
Available |
|
LTR™ trunking |
Available |
|
PassPort |
- |
|
Man Down function |
UT-124R |
|
Intrinsically safe |
- |
|
Vibration alert |
- |
|
Voice recorder |
- |
* One for UT-126H digital unit and one for another option board.
** Already installed,
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 F Method, Proc. |
---|---|
Low Pressure Storage |
500.4 I |
Low Pressure Operation |
500.4 II |
High Temperature Storage |
501.4 I |
High Temperature Operation |
501.4 II |
Low Temperature Storage |
502.4 I |
Low Temperature Operation |
502.4 II |
Temperature Shock |
503.4 I |
Solar Radiation |
505.4 I |
Rain Blowing |
506.4 I |
Rain Drip |
506.4 III |
Humidity Induced |
507.4 |
Salt Fog |
509.4 |
Dust Blowing |
510.4 I |
Vibration |
514.5 I |
Shock Functional |
516.5 I |
Shock Transit Drop |
516.5 IV |
Also meets equivalent MIL-STD-810 -C, -D and -E.
Ingress Protection Standards | |
---|---|
Dust & Water |
IP55 (Dust-protection and water jet resistance) |
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Battery pack, BP-232H
- Antenna, FA-SC55V
- Belt clip, MB-94
Please note that a Battery charger must be purchased separatelly.
MICROPHONES
EARPHONES
HEADSETS
PTT/VOX CABLES
CHARGERS
AC ADAPTERS
POWER SUPPLY CABLES
MOUNTING BRACKETS
BELT CLIPS
BELT HANGERS
ANTENNAS
INTERNAL UNITS
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-F3161D/IC-F4161D | 687KB |
IDAS™ Solutions | 2.43MB |
MDC1200 | 767KB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Operating guide for BIIS/MDC/LTR | IC-F3160/F4160 Series | |
Instructions | IC-F3161/IC-F3163, IC-F4161/IC-F4163 | |
Instruction Manual | IC-F3161/IC-F3163, IC-F4161/IC-F4163 Series | |
Instruction Manual | IC-F3161DT | For Rail Way |
Instruction Manual | IC-F3161DT/IC-F3161DS/IC-F4161DT/IC-F4161DS <FM> |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |