Descriptions
・Rapid charger cradle with Bluetooth® function
・Use an optional hand microphone wherever setting the transceiver into charger or attached to your waist.
・Hold up to seven Bluetooth® pairing information
Specifications
Charge Current | 940 mA |
---|---|
Power Supply Voltage | 12.0 ー 16.0 V DC |
Operating temperature range | +10℃~+40℃ |
Bluetooth® Version | Bluetooth® Version 3.0 |
Support Profile | HFP, HSP, A2DP, AVRCP |
Supplied AC adapter | BC-207S |
MOUNT BASE
-
- MBF-1
- MOUNTING BASE
-
- MBA-7
- BRACKET ADAPTER
-
- BC-218
- CHARGER CRADLE
POWER SOURCE
-
- BC-218
- CHARGER CRADLE
-
- BC-207S
- AC ADAPTER
-
- CP-22
- CIGARETTE LIGHTER CABLE
-
- CP-23L
- CIGARETTE LIGHTER CABLE
BC-207S is supplied with the BC-218.
SPEAKER MICROPHONE
-
- HM-215
- SPEAKER MICROPHONE
-
- BC-218
- CHARGER CRADLE
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
DOC (DECLARATION OF CONFORMITY) | BC-218 | |
DICHIARAZIONE DI CONFORMITA UE(ITALIANO) | BC-218 | |
INSTRUCTIONS | BC-218 |


Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |