7 W Output Power Plus New Antenna Provides 1.5 Times* More Communication Distance

1500 mW Powerful Audio and 1.5 Times* Higher Sound Pressure
* Approximate, comparing the IC-G86 with the IC-G80.

Optional 1500 mW Speaker-Microphone, HM-222HLWP
* For the transceiver with a "U" mark on the serial number label.
Dust-Protection, Water Resistance and a Tough Body
(IP54 and MIL-STD 810G)
19 Hours* of Long Lasting Battery Life
* At EX Hi Power mode. TX : RX : standby = 5 : 5 : 90 (The Power Save function is on.)
200 Channels with 5-character Alphanumeric Display
Automatic DTMF Transmission Linked to PTT
(on Pressing PTT (Log-in) / on Releasing PTT (Log-off))
Durable BNC Type Antenna Connector
Made in Japan Quality and Reliability
Other Features
- The rotary knob on the top panel is assignable either to volume control or channel selector
- Supplied BC-240, battery charger with a charging control function that prolongs the life of the battery
- Integrated VOX function
- Built-in CTCSS and DTCS encoder/decoder
- Priority, memory, skip and tone scanning
General
Frequency range (TX/RX guaranteed range) |
136–174 MHz |
||
---|---|---|---|
Type of emissions |
F2D, F3E (FM, FM-N) |
||
Number of channels |
200 channels |
||
Antenna impedance |
50 Ω |
||
Power supply requirement |
7.5 V DC |
||
Operating temperature range |
–20˚C to +60˚C, –4°F to +140°F |
||
Frequency stability |
±2.5 ppm (–20˚C to +60˚C, –4°F to +140°F) |
||
Current drain
(For the transceiver with a "U" mark on the serial number label.) |
TX (EX Hi/Hi/Mid/Low) |
1.6/1.4/1.0/0.5 A typical EXP1: 1.6/1.5/1.0/0.5 A typ. EXP2: 1.6/1.4/0.9/0.5 A typ. |
|
RX (Max. audio) |
450 mA typ. (INT SP), 190 mA typ. (EXT SP, Single end) 450 mA typ. (EXT SP, BTL) |
||
Dimensions (W×H×D) (Projections not included) |
58.6 × 112 × 30.5 mm, 2.3 × 4.4 × 1.2 in (with BP-298) |
||
Weight (Approximate) | 300 g, 10.6 oz (with BP-298, FA-B57V) |
Transmitter
Output power |
7.0/5.5/2.5/0.5 W (EX Hi/Hi/Mid/Low) |
|
---|---|---|
Maximum frequency deviation |
±5.0 kHz/±2.5 kHz (Wide/Narrow) |
|
Spurious emissions |
–80 dB typical |
|
External microphone connector |
3-conductor 2.5 (d) mm (1/10")/2.2 kΩ |
Receiver
Sensitivity |
–124 dBm typical |
||
---|---|---|---|
Squelch sensitivity | –126 dBm typical | ||
Selectivity (Wide/Narrow) | 75 dB typical/70 dB typical | ||
Intermodulation |
65 dB typical |
||
Audio output power (5% distortion with 8 Ω load) (For the transceiver with a "U" mark on the serial number label.) |
Internal SP |
1500 mW typical |
|
External SP |
450 mW typical (single end) |
||
External speaker connector |
3-conductor 3.5 (d) mm (1⁄8")/ 8 Ω |
All stated specifications are subject to change without notice or obligation.
Applicable U.S. Military Specifications
Standard |
|
|
---|---|---|
|
|
|
Low Pressure | 500.5 | I, II |
High Temperature | 501.5 | I, II |
Low Temperature | 502.5 | I, II |
Temperature Shock | 503.5 | I-C |
Solar Radiation | 505.5 | I |
Rain Blowing/Drip | 506.5 | I, III |
Humidity | 507.5 | II |
Salt Fog | 509.5 | – |
Dust Blowing | 510.5 | I |
Vibration | 514.6 | I |
Shock | 516.6 | I, IV |
Also meets equivalent MIL-STD-810-C, -D, -E and -F.
Applicable IP Rating
Ingress Protection Standard | ||
---|---|---|
Dust and Water | IP54 (Dust-protection, water resistance) |
All stated specifications are subject to change without notice or obligation
Supplied Accessories
- BP-298, battery pack
- BC-240, desktop charger
- BC-242, AC adapter
- MB-124, belt clip
- FA-B57V, antenna
MICROPHONES
HEADSETS
PTT/VOX CABLES
BATTERIES
CHARGERS
AC ADAPTERS
POWER SUPPLY CABLES
MOUNTING BRACKETS
BELT CLIPS
CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-G86 | 2.43MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
BASIC MANUAL | IC-G86 |



Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |