50W 100% Duty Cycle Operation
Employing a high performance power amplifier, together with the solid heatsink built into the chassis, the IC-FR5200H series provides a reliable 100% duty cycle operation at 50W output.
IDAS, Analog FM and Mixed Mode
The IC-FR5200H series is compatible with both analog FM mode and IDAS conventional and NXDN™ Type-D trunking* mode. Program digital and/or analog FM modes per channel. The mixed mode operation allows you to receive both analog FM and IDAS conventional modes and to transmit either mode depending on the received signal.
* Type-D Trunking and network controller functions are not available, depending on version.
32 Channel Capacity and 5 Programmable Buttons
The 12-digit dot-matrix display, 5 programmable buttons, 32 memory channels and internal speaker allow you to use the repeater as a simple base station or to check repeater activity. LEDs on the front panel show channel conditions.
Built-in Type-D Trunking and Network Controller*
The Type-D multi-site trunking/conventional functions are integrated in the repeater. The IP network capability extends your communication coverage and allows you to remotely control the repeater settings.
* Type-D Trunking and network controller functions are not available, depending on version.
D-SUB 25-pin Accessory Connector
The IC-FR5200H series has a programmable D-SUB 25-pin accessory connector for connecting external remote control devices. Also, modulation/demodulation signals can be input/output from the D-SUB connector.
Multiple CTCSS, DTCS Tone and RAN Code Decode
The IC-FR5200H series decodes multiple CTCSS and DTCS as well as digital RAN (Radio Access Number) codes on a per channel basis (up to 16 tones/codes) and downlinks the received signal with a specified tone/code. This function is useful for sharing a channel with multiple groups.
Other Features
- CW ID transmission
- ±0.5ppm high frequency stability (Digital mode)
- 2U low profile for 19-inch rack mount
- Digital voice scrambler provides 15-bit key (about 32,000 codes)
- Built-in inversion voice scrambler (Analog mode)
- Built-in audio compander (Analog mode)
- PTT priority setting (Local Mic., external PTT or repeater operation)
- 5-Tone and DTMF encoder/decoder (Analog mode)
- Normal and priority scan
- Convenient key assign stickers supplied
- Beat cancel capability
- Low voltage alert (Analog mode)
Rear Panel View

General
IC-FR5200H
|
IC-FR6200H
|
||
---|---|---|---|
Frequency coverage | 136–174MHz | 400–470, 450–512, 450–520, 350–400* MHz (* Non-FCC) |
|
Number of channels | Max. 32 channels | ||
Channel spacing | 6.25/12.5/25kHz* | ||
Type of emission | 16K0F3E, 11K0F3E/F7E/F7D/F7W, 4K00F1E/F1D/F3E |
||
Frequency stability | ±0.5ppm | ||
Antenna impedance | 50Ω (Type-N × 2) | ||
Operating temperature range | −30°C to +60°C; −22°F to +140°F | ||
Power supply voltage | 13.6V DC | ||
Current drain (at 13.6V DC) | TX 50W | 11A | |
RX Max. audio | 1.2A | ||
Stand-by | 550mA/450mA typ. (with/without UC-FR5000 at LCD backlight OFF) | ||
Dimensions (W×H×D) | 483×88×360 mm ; 19.02×3.46×14.17 in | ||
Weight | 10kg ; 22lb (approx.) |
*25kHz bandwidth is no longer available for FCC Part 90 licensees for USA versions. Ask your dealer if you need 25kHz bandwidth.
Transmitter
IC-FR5200H
|
IC-FR6200H
|
||
---|---|---|---|
Output power 100% duty cycle |
50W (adjustable to 5W) 50W (at 20–35°C, 24 hours) |
||
Max. frequency deviation | ±5.0kHz/±2.5kHz (W/N) | ||
Spurious emissions | 80dB typ. | ||
FM hum and noise | 52/49dB typ. (W/N) | 50/45dB typ. (W/N) | |
Audio harmonic distortion | 1% typ. (40% deviation) | ||
Digital FSK error | 5% Max. | ||
Microphone impedance | 600Ω (8-pin modular) |
Receiver
IC-FR5200H
|
IC-FR6200H
|
||
---|---|---|---|
Sensitivity | 12dB SINAD | 0.30μV typ. | 0.25μV typ. |
5% BER | 0.25μV typ. | 0.25μV typ. | |
Adjacent channel selectivity | 85/56dB typ. (W/N) 68dB typ. (Digital) |
78/56dB typ. (W/N) 63dB typ. (Digital) |
|
Spurious response | 80dB (W/N) 75dBμV emf (Digital) |
80dB (W/N) 80dBμV emf (Digital) |
|
Intermodulation rejection | 78dB typ. (W/N) 75dBμV typ. emf (Digital) |
78dB typ. (W/N) 75dBμV typ. emf (Digital) |
|
Hum and noise ratio | 52/50/66dB typ. (W/N/D) | 50/45/55dB typ. (W/N/D) | |
Audio output power | 4.0W typ. at 5% distortion with a 4Ω load | ||
External speaker connector | 2-conductor 3.5 (d) mm (1/8″)/4Ω |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 G Method, Proc. |
---|---|
Low Temperature Storage |
500.5 I |
Low Temperature Operation |
500.5 II |
High Temperature Storage |
501.5 I |
High Temperature Operation |
501.5 II |
Low Temperature Storage |
502.5 I |
Low Temperature Operation |
502.5 II |
Temperature Shock |
503.5 I-C |
Humidity |
507.5 II |
Vibration |
514.6 I |
Shock Functional |
516.6 I |
Also meets equivalent MIL-STD-810 -C, -D, -E and -F.
All stated specifications are subject to change without notice or obligation.
MICROPHONES
EXTERNAL SPEAKERS
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-FR5200H/IC-FR6200H | 283KB |
Business Radio Solutions (USA Edition) | 12.70MB |
IDAS™ Solutions | 2.43MB |



Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |