Two RF Modules in One Unit
The IC-FR5100/FR6100 series have an internal space for installing an optional RF unit, UR-FR5100 or UR-FR6100. Two RF modules can be installed in a chassis reducing installation space, and increasing channel capacity. They can be programmed and operated independently.
25W 100% Duty Cycle Operation*
Employing a high performance power amplifier, the IC-FR5100 series provides a reliable 100% duty cycle operation at 25W output. When need higher power, the optional UR-PA5000 series power amplifier provides 50W output power with 100% duty cycle.
* Ambient temperature: 25°C
19-inch Rack Mount Design, 2U Height Low Profile Design
The IC-FR5100/FR6100 series has a rack mount bracket and handles for installation in an industry standard 19-inch rack.
Multiple CTCSS and DTCS Tone Decode
The IC-FR5100/FR6100 series detects multiple CTCSS and DTCS on a channel (up to 16 tones on a table) and downlinks (transmits) the received signal with a specified tone. This function is useful for sharing a channel with multiple groups.
Base Station Operation
The IC-FR5100/FR6100 series has 5 programmable buttons, 12-digit dot-matrix display and 32 memory channels allowing you to use the repeater as a base station.
Other Features
- Programmable accessory connector (D-sub 25-pin) for connecting trunking controllers or other external devices
- 5-Tone and DTMF encoder/decoder
- CW ID transmitter
- Normal and priority scan setting
- Wide frequency coverage
- Built-in audio compander
- Built-in inversion type voice scrambler*
* Inversion type voice scrambler is not compatible with UT-109R/UT-110R voice scrambler.
General
IC-FR5100 |
IC-FR6100 |
|||
---|---|---|---|---|
Frequency coverage (Varies according to version) |
136-174 MHz |
400-470 MHz |
||
Number of channels |
32 ch |
|||
Channel spacing (Varies according to version) |
6.25/12.5/20/25 kHz |
|||
Type of emission |
16K0F3E, |
|||
Power supply requirement |
13.2V DC |
|||
Current drain (at 13.6V DC) |
Tx 25W |
8A |
7A |
|
Rx | Stand-by |
500mA*1 |
||
Max. audio |
1900mA |
|||
Dimensions (projections not included; W×H×D) |
483 × 88 × 260 mm |
|||
Weight (approx.) |
5.6kg |
*1 FAN, LCD backlight off
NXDN version |
||||
---|---|---|---|---|
Type-D multi-site trunking |
UC-FR5000 + CF-FR5000MT |
|||
Type-D single-site trunking |
UC-FR5000 |
|||
Type-C trunking |
- |
|||
Multi-site conventional |
UC-FR5000 + CF-FR5000MC |
|||
Digital voice scrambler |
available |
|||
DES Encryption |
- |
|||
AES Encryption |
- |
|||
CTCSS/DTCS (Encoder/Decoder) |
available |
|||
2-Tone (Encoder/Decoder) |
- |
|||
5-Tone (Encoder/Decoder) |
available |
|||
DTMF | autodial |
available |
||
decoder |
available |
|||
Voice Scrambler*1 | Inversion |
available |
||
MDC 1200 |
- |
|||
LTR™ trunking |
available*2 |
|||
GPS receiver |
- |
|||
Channel announcement |
- |
|||
Voice recorder |
- |
|||
IP rating |
|
|||
MIL standard |
MIL-STD-810-F |
*1 Inversion type voice scrambler is not compatible with UT-109R/UT-110R voice scrambler.
*2 External controller required.
Transmitter
IC-FR5100 |
IC-FR6100 |
|
---|---|---|
RF output power (High) |
25W (100% duty cycle) |
|
Spurious emissions |
0.25μW (≦1GHz) |
|
Frequency stability |
±0.2kHz |
±0.5kHz |
Audio harmonic distortion |
40% deviation |
|
Digital FSK error | 5% max. |
Receiver
IC-FR5100 |
IC-FR6100 |
||
---|---|---|---|
Sensitivity | at 20dB SINAD |
−4dBμV typ. (emf) |
|
at 5% BER |
−6dBμV typ. (emf) |
||
Adjacent channel selectivity |
86/83/77dB typ. (W/M/N) |
80/78/72dB typ. (W/M/N) |
|
Spurious response rejection |
86dB typ. (W/M/N) |
80dB typ. (W/M/N) |
|
Intermodulation rejection |
73dB typ. (W/M/N) |
72dB typ. (W/M/N) |
|
AF output power (at 5% distortion) |
3.5W (typ.) with a 4Ω load |
Function Comparison and Internal Unit Options
NXDN version | dPMR version | ||
dPMRTM | Mode 1 /Mode 2 | N/A | avilable |
Mode 2 Multi-site | N/A |
UC-FR5000 Version 12 |
|
Mode 3 Trunking | N/A | UC-FR5000SE*3 | |
NXDN | Type-D single site trunking | UC-FR5000 Version 01 | N/A |
Type-D multi-site trunking | UC-FR5000 Version 03 | N/A | |
Multi-Site conventional | UC-FR5000 Version 02 | N/A | |
Type-C multi-site trunking | N/A | N/A | |
Voice Scrambler (Digital) | available | ||
Voice Scrambler (Analogue)*1 | Inversion | available | |
CTCSS/DTCS | encoder | available | |
decoder | available | ||
5-Tone | encoder | available | |
decoder | available | ||
DTMF aitodial | available | ||
DTMF decoder | available | ||
BIIS1200 | N/A | ||
NDC 1200 | N/A |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 F Method, Proc. |
---|---|
High Temperature Storage |
501.4 I |
High Temperature Operation |
501.4 II |
Low Temperature Storage |
502.4 I |
Low Temperature Operation |
502.4 II |
Vibration |
514.5 I |
Shock Functional |
516.5 I |
Also meets equivalent MIL-STD-810 -C, -D and -E.
All stated specifications are subject to change without notice or obligation.
MICROPHONES
EXTERNAL SPEAKERS
CHANNEL MODULES
POWER AMPLIFIERS
INTERNAL UNITS
ADAPTER CABLES
CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
Business Radio Solutions (European Edition) | 9.96MB |
IDAS™ Solutions | 2.43MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
INSTRUCTION MANUAL | IC-FR5000/IC-FR5100/IC-FR6000/IC-FR6000-L/IC-FR6100 | |
Instruction Manual | IC-FR5100/IC-FR5100H/IC-FR6100/IC-FR6100H | |
DOC (DECLARATION OF CONFORMITY) | IC-FR5100/UR-FR5100 | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) | IC-FR5100/UR-FR5100 | |
DOC (DECLARATION OF CONFORMITY) | IC-FR6100/UR-FR6100 | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) | IC-FR6100/UR-FR6100 |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |