Two RF Modules in One Unit
![](/uploads/product/body/IC-FR5000_dPMR/20191213135040.jpg)
The IC-FR5000/FR6000 series has an internal space for installing an optional RF unit, UR-FR5000 or UR-FR6000. Two RF modules can be installed in a chassis reducing installation space, and increasing channel capacity. They can be programmed and operated independently.
50W Output at 50% Duty Cycle or 25W 100% Duty Cycle Operation*
Employing a high performance power amplifier, the IC-FR5000 series provides a reliable 100% duty cycle operation at 25W output. When operated at the high power setting of 50W, the repeater operates with a 50% duty cycle.
* Ambient temperature: 25°C
50W Output at 100% Duty Cycle or 100W 50% Duty Cycle Operation with Optional Power Amplifier*
When need higher power, the optional UR-PA5000/UR-PA6000 series power amplifier provides 100W output power with a 50% duty cycle and 50W output with 100% duty cycle.
* Ambient temperature: 25°C
19-inch Rack Mount Design, 2U Height Low Profile Design
The IC-FR5000/FR6000 series has a rack mount bracket and handles for installation in an industry standard 19-inch rack.
Multiple CTCSS and DTCS Tone Decode
The IC-FR5000/FR6000 series detects multiple CTCSS and DTCS on a channel (up to 16 tones on a table) and downlinks (transmits) the received signal with a specified tone. This function is useful for sharing a channel with multiple groups.
Base Station Operation
The IC-FR5000/FR6000 series has 5 programmable buttons, 12-digit dot-matrix display and 32 memory channels allowing you to use the repeater as a base station.
Other Features
- Programmable accessory connector (D-sub 25-pin) for connecting trunking controllers or other external devices
- 5-Tone and DTMF encoder/decoder
- CW ID transmitter
- Normal and priority scan setting
- Wide frequency coverage
- Built-in audio compander
- Built-in inversion type voice scrambler*
* Inversion type voice scrambler is not compatible with UT-109R/UT-110R voice scrambler.
General
IC-FR5000 |
IC-FR6000 |
|||
---|---|---|---|---|
Frequency coverage (Varies according to version) |
136-174 MHz |
400-470 MHz |
||
Number of channels |
32 ch |
|||
Channel spacing (Varies according to version) |
6.25/12.5/25 or 7.5/15/30 kHz |
|||
Type of emission |
16K0F3E, |
16K0F3E, |
||
Power supply requirement |
13.6V DC |
|||
Current drain (at 13.6V DC) |
Tx High |
15A |
||
Rx | Stand-by |
400mA*1 |
||
Max. audio |
1900mA |
|||
Dimensions (projections not included; W×H×D) |
483×88×260 mm |
|||
Weight (approx.) |
5.6kg; 12.3lb |
*1 Repeater operation only.
Transmitter
IC-FR5000 |
IC-FR6000 |
|
---|---|---|
RF output power (High) |
50W |
|
Spurious emissions |
80dB |
|
Frequency stability |
±0.5ppm |
|
Audio harmonic distortion |
1% typical |
|
FM Hum and Noise |
52dB typ. (W) |
50dB typ. (W) |
Digital FSK error | 5% max. |
Receiver
IC-FR5000 |
IC-FR6000 |
||
---|---|---|---|
Sensitivity | FM at 12dB SINAD |
0.25µV (typ.) |
|
Digital at 5% BER |
0.20μV (typ.) |
||
Adjacent channel selectivity (W/N) |
78/56dB typ. |
||
Spurious response rejection |
90dB typ. |
||
Intermodulation rejection |
78dB typ. |
||
AF output power (at 5% distortion) |
4.0W (typ.) with a 4Ω load |
Function Comparison and Internal Unit Options
IC-FR5000
|
||
---|---|---|
dPMR™ | Mode 1/Mode 2 |
available |
Mode 2 Multi-site Conventional |
UC-FR5000*2 |
|
Mode 3 Trunking |
UC-FR5000SE*3 |
|
Voice Scrambler (Digital) |
available |
|
Voice Scrambler (Analgue)*1 |
Inversion |
available |
CTCSS/DTCS | encoder |
available |
decoder |
available |
|
5-Tone | encoder |
available |
decoder |
available |
|
DTMF autodial |
available |
|
DTMF decoder |
available |
|
BIIS 1200 |
- |
|
MDC 1200 |
- |
*1 Inversion type voice scrambler is not compatible with UT-109R/UT-110R voice scrambler.
*2 IC-FR5000/FR6000 Mode 2 version only.
*3 IC-FC5000E external controller required. The IC-FR5000/FR6000 cannot be used as a base station in dPMR Mode 3.
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 F Method, Proc. |
---|---|
High Temperature Storage |
501.4 I |
High Temperature Operation |
501.4 II |
Low Temperature Storage |
502.4 I |
Low Temperature Operation |
502.4 II |
Vibration |
514.5 I |
Shock Functional |
516.5 I |
All stated specifications are subject to change without notice or obligation.
Catalogs / Brochures
Brochures Name | Size |
---|---|
IDAS™ Solutions | 2.43MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Instruction Manual | IC-FR5000/IC-FR6000 (dPMR) | |
dPMR controller | UC-FR5000 |
![](/media/images/common/modal_close.png)
![](/media/images/common/modal_close.png)
![](/media/images/common/modal_close.png)
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
![](/media/images/world/product/ip_modal_img.jpg)
![](/media/images/world/product/ip_modal_img_sp.jpg)
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |