Type-C Trunking Compatible
The IC-F5360D series provides NXDN™ Type-C trunking and NXDN™ conventional systems.
- Paging call
- Broadcast call
- All call
- Group call
- Individual call
- Status call
- Text message
- Emergency call
- Stun and Kill (RX)
- Radio check (RX)
- Over-the-air alias
- GPS
- 15-bit digital scrambler
- RAN (Radio Access Number)
- Digital/analog mixed mode operation (Conventional system)
Menu-driven User Interface
The menu-driven user interface provides easy and intuitive operation. The functions can be toggled with the left and right [P2] and [P3] buttons and allow you to perform various operations and settings.


Built-in GPS Receiver*
Your current position data can be attached to a voice or data (status or emergency signal) transmission and can be sent to dispatch stations.
* External GPS antenna required.
Transparent Data
When IC-F5360D series is connected to a PC or other external equipment, the transparent data function allows data communication in a digital mode. It can be used for remote telemetry system control or data applications.
D-Sub Accessory Connector
The IC-F5360D series has a D-Sub 15-pin ACC connector for connecting various external devices.
Optional Active Noise Canceling Microphone
The optional active noise canceling microphone HM-211 can automatically reduce noise in extremely noisy environments and assist in transmitting clear and accurate audio.
Watch the HM-211 performance video:
Other Features
- MIL-STD 810 G rugged construction
- 512 channels with 128 zones
- CTCSS/DTCS/DTMF encoder/decoder*
- MDC 1200 PTT ID transmission*
- Audio compander*
- Inversion voice scrambler*
- 4W front mounted speaker
(* = Analog mode only)
Rear View

General
IC-F5360D | IC-F6360D | |||
---|---|---|---|---|
Frequency coverage | 136–174MHz | 400–470MHz | ||
Number of channels | 512 channels/128 zones | |||
Type of emission | 8K50F3E, 8K30F1E/F1D, 4K00F1E/F1D | |||
Channel spacing | 15/12.5/6.25 kHz | |||
Power supply requirement | 13.6V DC | |||
Current drain (approx.) |
Tx (High) | 10A (50W) | 10A (45W) | |
Rx (Max./Standby) | 0.9A/250mA | |||
Antenna impedance | 50Ω (SO-239) | |||
Operating temperature range | −30°C to +60°C ; −22°F to +140°F | |||
Dimensions (W×H×D) (Projections not included) |
160×45×150mm; 6.3×1.77×5.91in | |||
Weight (approx.) | 1.3kg; 2.87lb |
Transmitter
IC-F5360D | IC-F6360D | |||
---|---|---|---|---|
Output power (at 13.6V DC) | 50W, 25W, 5W (Hi, L2, L1) |
45W, 25W, 4.5W (Hi, L2, L1) |
||
Max. frequency deviation | ±2.5kHz (Narrow) | |||
Frequency stability | ±1.0ppm | |||
Spurious emissions | 87dB typ. | 80dB typ. | ||
FM Hum and noise | 45dB typ. (Narrow) | 45dB typ. (Narrow) | ||
Audio harmonic distortion | 1% typ. (AF 1kHz 40% deviation) | |||
FSK error | 1% typ. (Digital 6.25/12.5kHz) | |||
Ext. microphone impedance | 600Ω (8-pin modular) |
Receiver
IC-F5360D | IC-F6360D | |||
---|---|---|---|---|
Sensitivity | Analog | 0.25μV typ. (12dB SINAD) | ||
Digital | −9dBμV emf typ. (0.18 μV typ.) (5% BER) | |||
Adjacent channel selectivity | 70/70/59dB typ. (Narrow/D 12.5kHz/D 6.25kHz) | |||
Spurious response rejection | 80dB typ. | |||
Intermodulation rejection | 75/70/70dB typ. (Narrow/D 12.5kHz/D 6.25kHz) | |||
Hum and noise | 40dB typ. (Narrow) | |||
Audio output power | 4W typ. (at 5% distortion, 4Ω load) | |||
Ext. speaker connector | 2-conductor 3.5 (d) mm (1/8″)/4Ω |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 G Method, Proc. |
---|---|
Low Pressure Storage |
500.5 I |
Low Pressure Operation |
500.5 II |
High Temperature Storage |
501.5 I |
High Temperature Operation |
501.5 II |
Low Temperature Storage |
502.5 I |
Low Temperature Operation |
502.5 II |
Temperature Shock |
503.5 I-C |
Solar Radiation |
505.5 I |
Humidity |
507.5 II |
Vibration |
514.6 I |
Shock Functional |
516.6 I |
Shock Transit Drop |
516.6 IV |
Also meets equivalent MIL-STD-810 -C, -D, -E and -F.
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Hand microphone (HM-148G)
- DC power cable
- Mounting bracket kit
- Microphone hanger
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-F5360D/IC-F6360D Digital Series | 338KB |
IDAS™ Solutions | 2.43MB |



Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |