Built-in Basic LTR™ Mode Operation
Group, selective and phone calls are available in built-in LTR™ mode. MDC signaling is also available on LTR™ mode.
Optional 6.25 kHz Digital Mode Ready
Optional 6.25 kHz Digital Mode is Available.
Built-in Versatile Tone Signaling
Use the built-in CTCSS, DTCS, 2-Tone 5-Tone or MDC 1200 capability to set up your own talk groups, and have your radio standby quietly when other groups are talking. Up to 10 2-Tone, 8 5-Tone codes can be decoded on a single memory channel.
IP54 Dust-Protection and Splash Resistance (Controller Only)
When used with the optional separation kit, RMK-3, and separation cable, the front panel of the IC-F5061 series can be detached from the main unit. The control head has dust-protection and splash resistance construction equivalent to IP54.
Voting Scan
The voting mode scanning detects the S-meter level of repeater stations and automatically selects the strongest station or the first station to exceed the preset S-meter level, useful for roaming 2 or more repeater sites.
Optional Active Noise Canceling Microphone
The optional active noise canceling microphone HM-211 can automatically reduce noise in extremely noisy environments and assist in transmitting clear and accurate audio.
Watch the HM-211 performance video:
Other Features
- The mode slave setting automatically selects the scanning list, according to the operating channel
- Nuisance delete
- Built-in inversion-type voice scrambler
- Large dot matrix display and multi-function LCD
- 8 DTMF autodialing memories and ANI function
- D-Sub accessory connector, ignition sensing line and more...
General
IC-F5063 | IC-F6063 | |||
---|---|---|---|---|
Frequency coverage (Varies according to version) |
136-174 MHz |
400–470 MHz |
||
Number of channels |
512 ch/128 zones |
|||
Channel spacing (Varies according to version) |
12.5/25, 15/30 |
12.5/25 |
||
Type of emission |
16K0F3E, |
16K0F3E, |
||
Current drain | Tx High |
14A/7A (50/25W) |
14A/7A (45/25W) |
|
Rx | Stand-by |
300 mA |
||
Max. audio |
1.2A |
|||
Dimensions (projections not included; W×H×D) |
160×45×150 mm |
|||
Weight (approx.) |
1.3kg; 2.9lb |
Transmitter
IC-F5063 | IC-F6063 | |
---|---|---|
RF output power |
25W |
|
Spurious emissions |
75dB (typ.) |
|
Frequency stability |
±1.0ppm |
|
Audio harmonic distortion |
3% typical |
|
FM Hum and Noise |
45dB typ. (W) |
Receiver
IC-F5063 | IC-F6063 | |
---|---|---|
Sensitivity at 12dB SINAD |
0.25μV (typ. analog), |
|
Adjacent channel selectivity (W/N) |
85/75dB (typ.) |
|
Spurious response rejection |
90dB (typ.) |
|
Intermodulation rejection |
77dB (typ.) |
|
AF output power (at 5% distortion with an 8Ω load) |
4W (typ.) |
Function Comparison and Internal Unit Options
IC-F5063 IC-F6063 |
||
---|---|---|
Number of option slots | 2* | |
CTCSS/ DTCS | encoder | Available |
decoder | Available | |
2-Tone | encoder | Available |
decoder | Available | |
5-Tone | encoder | Available |
decoder | Available | |
DTMF autodial | Available | |
DTMF decoder | Available** | |
Voice Scrambler | Inversion | Available |
APCO P25 digital | - | |
AES encryption | - | |
DES encryption | - | |
IDAS digital | UT-126H | |
MPT 1327 | - | |
MDC 1200 | Available | |
LTR™ trunking | Available | |
PassPort | - |
* One for UT-126H digital unit and one for another option board.
** Possible as a kind of 5-Tone format.
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard |
MIL-810 G | |
---|---|---|
Method | Procedure | |
High Temperature Storage | 501.4 | I |
High Temperature Operation | 501.4 | II |
Low Temperature Storage | 502.4-3 | I |
Low Temperature Operation | 502.4-3 | II |
Temperature Shock | 503.4 | I |
Rain Blowing | 506.4 | I* |
Rain Drip | 506.4 | III* |
Humidity Induced | 507.4 | 507.4 |
Vibration | 514.5 | I |
Shock Functional | 516.5 | I |
Shock Transit Drop | 516.5 | IV |
* Rain blowing and drip tests were performed on the controller and RMK-3 only.
Also meets equivalent MIL STD 810 -C, -D and -E.
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Microphone, HM-152
- Microphone hanger and its cable
- Mounting bracket kit
- DC power cable
- Function name sticker
MICROPHONES
EXTERNAL SPEAKERS
POWER SUPPLY CABLES
SEPARATION KITS
INTERNAL UNITS
EXTENSION CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-F5063/IC-F6063 | 661KB |
IDAS™ Solutions | 2.43MB |
MDC1200 | 767KB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Instruction Manual | IC-F5060 series, IC-F6060 series | |
Operating guide | IC-F5060/F6060 series (BIIS / MDC / LTR / NXDN operation) |



Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |