Simple Operation for Instant Communication
The IC-F5012 series has 8 channels. The P0-P3 programmable buttons allows you to customise the radio to suit your needs and convenience.
Most Popular Signalings Built-in
Use the built-in 2-Tone, 5-Tone, MDC 1200, CTCSS and DTCS capabilities as standard to set up your own talk groups and quiet stand-by when others are talking.
Multiple 2-Tone, Multiple 5-Tone
Up to ten 2-Tone or eight 5-Tone codes can be decoded on a channel. Features such as stun, kill, revive, answer back, auto TX, scan, audio output are programmable to respond to each tone.
MDC 1200 Compatible
The IC-F5012 series has a built-in MDC 1200 for transmitting a PTT ID and emergency* signal and for receiving radio check, stun and revive. Assimilate the radio easily into existing MDC 1200 systems.
* No ACK transmission
Enhanced Scan Features
The priority scan function allows you to monitor one or two priority channels while scanning other non-priority channels. The Tx channel and talk back functions allow you to make a quick response while scanning.
Remote Channel Control with Optional ACC Cable

Photo includes optional OPC-2078.
The optional ACC cable allows you to connect with various external devicesto control audio output, modulated signal input, remote channel control, horn honk and many more functions. OPC-1939 is a D-SUB 15-pin type and OPC-2078 is a D-SUB 25-pin type.
Built Military Rugged
The IC-F5012 series is tested to MIL-STD 810 F specifications. The radio is built to survive harsh environment and keep working.
Other Features
- 4W (typ.) front mounted speaker
- Wide frequency coverage (136–174 and 400–470MHz)
- Wide/middle/narrow channel spacing (25, 20, 12.5kHz)
- Microphone hanger action programmable
- Optional DTMF microphone (HM-152T/HM-148T)
- DTMF autodial function
- PC programmable
- Talk around function
- Power-on password function
- Nuisance delete function
- Time-out-timer, lock-out penalty timer
General
IC-F5012 |
IC-F6012 |
|||
---|---|---|---|---|
Frequency coverage |
136-174MHz |
400-470MHz |
||
Number of channels |
8 channels |
|||
Channel spacing |
25/20/12.5kHz |
|||
Type of emission |
16K0F3E, 14K0F3E, 8K50F3E |
|||
Current drain (approx.) |
Tx | High (25W) |
5A |
|
Rx | Stand-by |
250mA |
||
Max. audio |
700mA |
|||
Dimensions (projections not included; W×H×D) |
150×40×117.5 mm |
|||
Weight |
0.8kg |
Transmitter
IC-F5012 |
IC-F6012 |
|
---|---|---|
RF output power |
25W, 10W, 2.5W (Hi, L2, L1) |
|
Spurious emissions |
0.25μV (≤1GHz) |
|
Frequency stability |
±2.5ppm |
|
Audio harmonic distortion |
3% typ. (AF 1kHz 40% deviation) |
|
Residual modulation (W/M/N) |
55/53/50dB typ. |
Receiver
IC-F5012 |
IC-F6012 |
|
---|---|---|
Sensitivity at 20dB SINAD | –4dBμV (typ.) emf | |
Adjacent channel selectivity (W/M/N) |
75/75/65dB (typ.) |
|
Spurious response rejection |
70dB min. |
|
Intermodulation rejection |
67dB (typ.) |
|
AF output power (at 5% distortion with an 4Ω load) |
4W (typ.) |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 F Method, Proc. |
---|---|
Low Pressure Storage |
500.4 I |
Low Pressure Operation |
500.4 II |
High Temperature Storage |
501.4 I |
High Temperature Operation |
501.4 II |
Low Temperature Storage |
502.4 I |
Low Temperature Operation |
502.4 II |
Temperature Shock |
503.4 I |
Solar Radiation |
505.4 I |
Humidity Induced |
507.4 |
Settling Dust |
510.4 III |
Vibration |
514.5 I |
Shock Functional |
516.5 I |
Shock Transit Drop |
516.5 IV |
Also meets equivalent MIL STD 810 -C, -D and -E.
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Microphone, HM-152
- Microphone hanger and its cable
- Mounting bracket kit
- DC power cable
- Function name sticker
MICROPHONES
EXTERNAL SPEAKERS
EXTENSION CABLES
ADAPTER CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-F5012/IC-F6012 | 238KB |
Business Radio Solutions (European Edition) | 5.18MB |
IDAS™ Solutions | 2.43MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Instructions | IC-F5010 series, IC-F6010 series | |
DOC (DECLARATION OF CONFORMITY) | IC-F5012 | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) | IC-F5012 | |
DOC (DECLARATION OF CONFORMITY) | IC-F6012 | |
DICHIARAZIONE DI CONFORMITA UE(ITALIANO) | IC-F6012 |



Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |