Icom’s Custom High Power Handling Capacity Speaker for 1500 mW of Powerful Audio
Optional 1500 mW Speaker-Microphone, HM-222HLWP*
* For the transceiver with a "U" mark on the serial number label.
Compact, Waterproof Durable Design (IP67/55/54 and MIL-STD-810-G)
Multiple Operating Modes*
- Analog FM
- NXDN™ /dPMR™ conventional
- NXDN™ Type-D single-site trunking
*Available protocol differs depending on the version.
Over-the-Air Alias (OAA) Function Displays the Caller’s Name without Programming
(IC-F1100DT/DS and IC-F2100DT/DS only)
AquaQuake™ Function Clears Any Water Ingress That May Penetrate the Speaker Grill of the Unit
Motion/Stationary Detection, Man Down and Lone Worker Functions
Operating Time of Up To 18 Hours with the Supplied Battery (BP-280)
IDAS™ Conventional and Type-D Single-Site Trunking
General Features
- 136–174, 350–400, 400–470, 450–512, 450–520 MHz versions
- 128 Channels / 8 Zones (for LCD types)
- 16 Channels (for non-display types)
- Icom’s customized speaker offers a louder 1500 mW audio output
- An engineered casing that amplifies and improves acoustic sound clarity
- Compact (52.2 (W) × 111.8 (H) mm; 2.1 × 4.4 in) and lightweight
- IP67/55/54 waterproof and dust-tight protection
- Tested to 12 categories of MIL-STD-810-G environmental tests
- AquaQuake™ – Expels water ingress from the speaker grill
- DTMF autodial memories
- 16-position rotary selector and ON/OFF volume knob
- Programmable keys – Increase the number of programmable key assignments by using the “Shift key”
- Operating times of up to 18 hours (with the supplied BP-280 battery pack)
- Eight character alphanumeric display (for LCD types)
- Three color LED
Operating Mode*
- NXDN or dPMR Mode 1/Mode 2 conventional
- NXDN or dPMR multi-site conventional over IP network
- NXDN Type-D single-site trunking
- Analog mode
- Analog/digital mixed operation (conventional mode)
(* Available protocol differs depending on the version)
Digital Functions (Voice and Data)
- AMBE+2™ vocoder
- Over-the-Air Alias (OAA) displays the caller’s name without programming (for LCD types)
- Individual, Group and All call
- Late entry for Group call
- Status call and Polling
- Short data messages (for LCD types)
- Call alert (NXDN)
- Radio check (RX only) (NXDN)
- GPS position capabilities (requires HM-171GPW)
- Up to 500 ID numbers for IDAS or MDC 1200 signaling system can be saved in the Call List to show the alias name
Analog Functions
- CTCSS and DTCS tone
- 2-Tone and 5-Tone
- MDC functions*; PTT ID, Emergency (TX/RX), Radio check (RX), Stun (RX), Revive (RX)
- BIIS PTT ID transmission
* Depending on the version
Safety and Security
- Digital voice scrambler* (Low level encryption)
* Voice Scrambler function is not available depending on the transceiver version. - Radio Stun/Revive/Kill (RX only)
- Remote monitor (NXDN)/ambience listening (dPMR)
- Man down, Lone worker and Emergency call key capability
- Motion and Stationary detection function
- Surveillance function temporarily turns OFF the beep and LED indicator
- Power ON password (for LCD types)
Scan Functions
- Priority scan monitors one or two priority channels while scanning non-priority channels
- Voting scan automatically selects the optimal repeater site
- Mode dependent scan automatically changes the scan list, depending on the operating channel
- Power ON scan function
- Talk Back timer
Voice/Audio Functions
- Channel announcement function
- VOX function for hands-free operation
- Siren sound for security alarm
General
IC-F1100DT/S | IC-F1100D | IC-F2100DT/S | IC-F2100D | ||
---|---|---|---|---|---|
Frequency coverage* (*Varies according to version) |
136–174 MHz (NXDN/dPMR) | 350–400 MHz (NXDN, EXP, IC-F2100D only) 400–470 MHz (NXDN/dPMR USA/EUR/EXP) 450–512 MHz (NXDN, USA) 450–520 MHz (NXDN, EXP) |
|||
Number of channels |
128 channels/ 8 zones |
16 channels | 128 channels/ 8 zones | 16 channels | |
Type of emission* (*Depending onversion) |
11K0F3E, 4K00F1E, 4K00F1D (USA) |
||||
16K0F3E, 14K0F3E, 11K0F3E, 8K50F3E, 4K00F1E, 4K00F1D (EXP) |
|||||
16K0F3E, 14K0F3E, 8K50F3E, 4K00F1E, 4K00F1D (EUR) |
|||||
Power supply requirement |
7.5V DC nominal |
||||
Current drain (approx.) |
Tx |
1.3A |
1.6 A (at 5 W) |
||
Rx |
520 mA /110 mA |
520 mA /110 mA |
|||
Antenna impedance |
50Ω |
||||
Operating temperature range (Radio specification) |
–30°C to +60°C; –22°F to +140°F (Radio specification) |
||||
–25°C to +55°C (Radio specification) |
|||||
Dimensions (W × H × D; Projections not included) |
IC-F1100DS/D, IC-F2100DS/D: IC-F1100DT, IC-F2100DT: |
||||
Weight (approx.) |
IC-F1100D, IC-F2100D: 258 g, 9.1 oz (With BP-280 and MB-133) |
Transmitter
IC-F1100DT/S | IC-F1100D | IC-F2100DT/S | IC-F2100D | ||
---|---|---|---|---|---|
Output power (Hi, L2, L1) |
5 W, 2 W, 1 W |
5 W, 2 W, 1 W |
|||
Maximum frequency deviation |
± 5.0 kHz (25 kHz), ±4.0 kHz (20 kHz), ±2.5 kHz (12.5 kHz) |
||||
Spurious emissions |
70 dB minimum (USA/EXP) |
||||
0.25 μW (≤ 1 GHz), 1.0 μW (> 1 GHz) (EUR/EXP) |
|||||
Frequency stability |
±2.0ppm |
±1.0ppm |
|||
Audio harmonic distortion |
0.8% typ. (25 kHz), |
0.7% typ. (25 kHz), |
|||
FM Hum and Noise (without CCITT filter) |
46 dB typ. (25 kHz) (EXP), |
44 dB typical (12.5 kHz) (USA) |
|||
Residual modulations (with CCITT filter) |
51 dB typical (25 kHz), |
54 dB typical (25 kHz), |
|||
FSK error |
5% maximum |
||||
External microphone connector |
3-conductor 2.5 (d) mm (1/10 in)/2.2 kΩ |
Receiver
IC-F1100DT/S | IC-F1100D | IC-F2100DT/S | IC-F2100D | ||
---|---|---|---|---|---|
Sensitivity | Analog (at 12dB SINAD) |
0.24 μV typical |
0.24 μV typical |
||
Analog (at 20dB SINAD) |
–5 dBμV typ. emf (25/20 kHz), |
–5 dBμV typ. emf (25/20 kHz), |
|||
Digital (at 5% BER) |
–9 dBμV typical emf |
–8 dBμV typical emf |
|||
Adjacent channel selectivity |
77 dB typ. (25 kHz), |
76 dB typ. (25 kHz), |
|||
Spurious response rejection |
80 dB typical |
||||
Intermodulation rejection | Digital |
71 dB typ. (USA/EXP), |
70 dB typ. (USA/EXP), |
||
Analog |
76 dB typ. (25 kHz, EXP), |
77 dB typ. (25 kHz, EXP), |
|||
Hum and noise | (With CCITT filter) |
48 dB typ. (25 kHz, EXP), |
42 dB typical (12.5 kHz, USA) |
||
(Without CCITT filter) |
51 dB typ. (25 kHz), |
50 dB typ. (25 kHz), |
|||
AF output power (at 5% distortion 8Ω load ) |
Internal SP |
1500 mW typical |
|||
External SP |
450 mW typical (single end ) |
400 mW typical(single end ) |
|||
External speaker connector |
2-conductor 3.5 (d) mm (1⁄8 in)/8 Ω |
All stated specifi cations are subject to change without notice or obligation.
Measurements made in accordance with TIA-603 (USA/EXP) or EN 300-086 (EUR).
* For the transceiver with "U" make on the serial number label.
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard |
MIL-810 G | |
---|---|---|
Method | Procedure | |
Low Pressure |
500.5 |
I, II |
High Temperature |
501.5 |
I, II |
Low Temperature |
502.5 |
I, II |
Temperature Shock |
503.5 |
I-C |
Solar Radiation |
505.5 |
I |
Rain Blowing/Drip |
506.5 |
I, III |
Humidity |
507.5 |
II |
Salt Fog |
509.5 |
– |
Dust Blowing |
510.5 |
I |
Immersion |
512.5 |
I |
Vibration |
514.6 |
I |
Shock |
516.6 |
I, IV |
Also meets equivalent MIL-STD-810 -C, -D, -E and -F.
Ingress Protection Standard | |
---|---|
Dust & Water |
IP67 (Dust-tight and Immersion) |
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Battery pack, BP-280
- Belt clip, MB-133
- Antenna
- Desktop charger, BC-213*
- AC adapter*, BC-242 (or BC-123SE/SUK/SV)
* May differ, or not supplied, depending on the version.
MICROPHONES
HEADSETS
PTT/VOX CABLES
CHARGERS
AC ADAPTERS
POWER SUPPLY CABLES
MOUNTING BRACKETS
BELT CLIPS
ANTENNAS
Catalogs / Brochures
Brochures Name | Size |
---|---|
Professional Radios | 12.11MB |
Business Radio Solutions (European Edition) | 9.96MB |
IDAS™ Solutions | 2.43MB |
IDAS™ Digital Simulcast | 1.71MB |
IC-F1100D/IC-F2100D Series (without Voice scrambler) | 1.36MB |
IC-F1100D/IC-F2100D Series(A4) | 1.50MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Precautions(French) | IC-F1000 seris, IC-F1100D series, IC-F2000 series, IC-F2100D series | |
Instructions | IC-F1100D series, IC-F2100D series | |
DOC (DECLARATION OF CONFORMITY) | IC-F1100D/IC-F1100DS/IC-F1100DT | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) | IC-F1100D/IC-F1100DS/IC-F1100DT | |
DOC (DECLARATION OF CONFORMITY) | IC-F2100D/IC-F2100DS/IC-F2100DT | |
DICHIARAZIONE DI CONFORMITA UE(ITALIANO) | IC-F2100D/IC-F2100DS/IC-F2100DT |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |