Stable 65 W of Output Power*
The IC-2300H can generate 65W of output power. The rugged aluminum diecast provides effective heat dissipation and keeps RF output even during high duty cycle continuous transmission.
* Output power differs depending on version and specific regulatory requirements.
A Total of 207 Memory Channels
The IC-2300H has a total of 207 memory channels, including 200 regular channels, 6 scan edges and 1 call channel. The channel name is programmable with 6 characters for easy recognition.
Built-in CTCSS and DTCS Encoder/Decoder
The CTCSS and DTCS tones are built-in for quiet stand-by and repeater access. The tone scan function detects the subaudible tone that is used for repeater access. The pocket beep function gives you an audible and visual indicator of an incoming call.
The DTCS encoder function (DTCS transmit only) is also available.
Simple Operation
The IC-2300H retains the basic panel layout and its user interface from the IC-2200H. A 70.6×20 mm LCD display offers a good viewing angle suitable for mobile operation. The bottom of the display indicates the available functions of the front panel buttons directly below the display.
Multiple Scan Functions
The IC-2300H supports various scan types for maximum reception and ease of use. The DMS (Dynamic Memory Scan) system allows you to scan selected banks from 10 memory banks by simply adding and deleting bank links.
Tested to the MIL-STD 810 G Specifications
The IC-2300H is built tough to protect from a rough road. It has been tested to and has passed the latest MIL-STD 810 G specifications including shock, vibration and temperature tests.
Optional Active Noise Canceling Microphone
The optional active noise canceling microphone HM-209 can automatically reduce noise in extremely noisy environments and assist in transmitting clear and accurate audio.
Watch the HM-209 performance video:
Other Features
- Power supply voltage display
- Wide/narrow channel setting
- 4.5 W (typical) loud audio
- Reduced depth dimensions
- DTMF autodial
- Time-out timer
- Repeater lockout
- Automatic power off
- S-meter squelch
- Selectable LCD backlight color (amber, yellow and green)
- Weather channel receive and alert function (USA version only)
- Automatic repeater function (USA version only)
- Selectable squelch delay from short and long
- Squelch attenuator reduces suppression from strong signals
- PC to transceiver and transceiver to transceiver cloning capability
(Optional cloning software, CS-2300H and/or cloning cable required)
General
Number of channels | 207 channels (including 6 scan edges, and 1 call) |
||
---|---|---|---|
Type of emission | F2D, F3E (FM) | ||
Power supply requirement | 13.8 V DC ±15% | ||
Current drain | Tx (65 W) | 11 A | |
Rx | Stand-by | 0.4 A | |
Max. audio | 1.5 A | ||
Antenna impedance | 50 Ω (SO-239) | ||
Operating temperature range | –10°C to +60°C; 14°F to +140°F | ||
Dimensions (projections not included; W×H×D) |
140×40×162 mm; 5.5×1.6×6.4 in |
||
Weight (approx.) | 1.1 kg; 2.43 lb |
* Guaranteed range TX/RX: 144–148 MHz
Transmitter
Output power* (at 13.8 V DC) | 65 W, 25 W, 10 W, 5 W | |
---|---|---|
Max. frequency deviation | Wide | ±5.0 kHz |
Narrow | ±2.5 kHz | |
Spurious emissions | Less than –60 dBc | |
Frequency stability | ±3 ppm | |
Microphone impedance | 600 Ω (8-pin modular) |
* Output power differs depending on version and specific regulatory requirements.
Receiver
Intermediate frequencies | 46.35 MHz/450 kHz | |
---|---|---|
Sensitivity at 12dB SINAD | Less than 0.18 μV | |
Adjacent channel selectivity |
Wide | More than 6 kHz (at 6 dB) Less than 14 kHz (at 60 dB) |
Narrow | More than 3 kHz (at 6 dB) Less than 9 kHz (at 55 dB) |
|
Spurious response rejection | More than 60 dB | |
Audio output power | 4.5 W typ. (10% dist. 4 Ω load) | |
External speaker connector | 2-conductor 3.5 (d) mm (1⁄8ʺ)/4 Ω |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard |
MIL-810 G | |
---|---|---|
Method | Procedure | |
Low Pressure | 500.5 | I, II |
High Temperature | 501.5 | I, II |
Low Temperature | 502.5 | I, II |
Temperature Shock | 503.5 | I-C |
Solar Radiation | 505.5 | I |
Vibration | 514.6 | I |
Shock | 516.6 | I, IV |
Also meets equivalent MIL-STD-810-C, -D -E and -F.
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Remote control Mic, HM-133V
- Mounting bracket kit
- Microphone hanger*
- DC power cable
- Spare fuses
(* Depending on version)
MICROPHONES
EXTERNAL SPEAKERS
POWER SUPPLY CABLES
SOFTWARE
PROGRAMMING/DATA CABLES
EXTENSION CABLES
ADAPTER CABLES
CABLES
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-2300H(Amateur) | 418KB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Instruction Manual | IC-2300H | |
Quick Guide | IC-2300H | |
Quick Guide (with marine features) | IC-2300H |
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |