Simple operation for instant communication
The IC-F3002 series is so easy to use there’s no special training required. The few knobs and buttons are generously sized for easy operation and are designed to provide non-slip, positive action – even while wearing gloves.
Easy to hear in noisy areas
The radio provides 1500 mW* loud and clear audio with Icom custom high power handling capacity speaker. Clear communication is available even in noisy environments.
* Typical with internal speaker
Optional 1500 mW Speaker-Microphone, HM-222HLWP*
The combination of the optional HM-222HLWP and the IC-F3002 series* also provides 1500 mW (typ.) loud audio from the attached speaker-microphone.
* For the transceiver with a "U" mark on the serial number label.
Longer operating time
A new high efficiency FET of the IC-F3002 series reduces consumption current and provides up to 31 hours* of operating time with the BP-299, 3150 mAh (typical) supplied battery pack.
* TX: RX: Standby=5: 5: 90. Power save function ON.
Weather resistant, dust protection, military rugged
While the radio is a compact unit with a height of only 111 mm, the radio is tested to dust protection and water resistant equivalent to IP54 and 11 categories of MILSTD- 810 environmental tests. In short, the IC-F3002 series is built rugged!
Internal VOX capability for hands-free operation
The radio has the internal VOX capability for hands-free operation. Optional compatible headset with plug adapter cable OPC-2004LA can be used with the radio. Also, the VOX gain and VOX delay time are adjustable.
Selective calling, quiet stand-by and more
2-Tone and 5-Tone signaling gives you selective calling, quiet stand-by and other convenient functions with programming. The radio “stun” function disables a radio over the air and the “revive” function restores the stunned radio.
Scan features
The priority scan allows you to monitor one or two priority channels while scanning other non-priority channels. The TX channel and talk back functions allow you to make a quick response while scanning.
Other features
- DTMF autodial
- CTCSS/DTCS encoder/decoder
- BIIS PTT ID transmission
- MDC PTT ID and emergency
- Low battery alert
- 2-step power save
- PC programmable
- Time out timer
- Talk around function
- Lone worker function
- Enhanced emergency
- 3-color LED
- Surveillance function
General
IC-F3002 | IC-F4002 | |||
---|---|---|---|---|
Frequency range (Varies according to version) |
136 MHz–174 MHz |
400–470 MHz |
||
Number of memory channels |
16 channels |
|||
Type of emission |
8K50F3E/14K0F3E/16K0F3E |
|||
Channel spacing |
12.5/20/25 kHz |
|||
Power supply requirement | 7.2 V DC | |||
Current drain (approximate) |
Tx | High |
1.3 A |
1.6 A |
Rx | Stand-by |
75 mA |
70 mA |
|
Max. audio |
500 mA (Internal SP) |
|||
Antenna impedance | 50 Ω | |||
Operating temperature range | –25°C to +55°C (Radio only) | |||
Dimensions (W×H×D) (Projections are not included) |
58 × 111 × 35.5 mm (With BP-299) |
|||
Weight (approximate) |
272 g (With BP-299) |
Transmitter
IC-F3002 | IC-F4002 | |
---|---|---|
RF output power (at 7.2V DC) |
5 W, 2 W, 1 W (Hi, L2, L1) |
|
Max. frequency deviation | ± 5.0 kHz/±4.0 kHz/±2.5 kHz (Wide/Middle/Narrow) | |
Frequency stability |
±2.5 ppm |
|
Spurious emissions |
0.25 μW (≤ 1 GHz) |
|
Residual modulations | 58/56/53 dB typical (Wide/Middle/Narrow) |
53/51/48 dB typical (Wide/Middle/Narrow) |
Audio harmonic distortion (AF 1 kHz 40% deviation) |
1.0%/1.0%/1.5% typical |
|
Ext. microphone connector | 3-conductor 2.5 (d) mm (1/10″)/2.2 kΩ) |
Receiver
IC-F3002 | IC-F4002 | ||
---|---|---|---|
Sensitivity (at 20 dB SINAD) |
–4 dBμV typical emf |
||
Adjacent channel selectivity |
78/78/70 dB typical |
73/73/65 dB typical |
|
Spurious response rejection |
70dB (min.) |
||
Intermodulation rejection |
65 dB minimum |
||
Hum and noise (With CCITT filter) | 57/55/51dB typical (Wide/Middle/Narrow) |
52/50/47 dB typical (Wide/Middle/Narrow) |
|
Audio output power (at 5% distortion 8Ω load ) |
Internal SP |
1500 mW typical |
|
External SP |
400 mW typical |
||
Ext. speaker connector | Ext. speaker connector |
* For the transceiver with "U" make on the serial number label.
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard |
|
||
---|---|---|---|
|
|
Simple explanation (radio specifications are not changed after each test) |
|
Low Pressure |
500.5 |
I, II |
Keep the transceiver 20℃/101.3 kPa and 25℃/57.2 kPa for a total of 7 hours |
High Temperature |
501.5 |
I, II |
Keep the transceiver between 30 to 63℃ for a total of 168 hours |
Low Temperature |
502.5 |
I, II |
Keep the transceiver at -25℃ for 4 hours |
Temperature Shock |
503.5 |
I-C |
Keep the transceiver at -51℃/2 h and +71℃/2 h × 3 cycles (total 12 hours) |
Solar Radiation |
505.5 |
I |
Keep the transceiver at 49℃ and 1120 W/m2 for 24 h × 3 cycles (for a total of 72 hours) |
Rain Blowing/Drip |
506.5 |
I, III |
I : Blast 1.7 mm/min rain with 18 m/s wind for 30 min to 6 surfaces (for a total of 180 min) III: Drip water 2800 l/m2/h for 15 min. |
Humidity |
507.5 |
II |
Keep the transceiver at 95% humidity with 30℃ and 60℃ for 240 hours. |
Salt Fog |
509.5 |
- |
Spray 5% salt water with 1-3 ml/h at 80 cm 2 under 35℃/95% condition for 24 hours then dry it under 24℃/50% condition × 2 cycles |
Dust Blowing |
510.5 |
I |
Blowing talc powder Temp/time: 23℃/6 h and 60℃/6 h, humidity: less than 30%, wind speed: 8.9 m/s, powder density: 10 ±7 g/m3 |
Vibration |
514.6 |
I | Vibrate the transceiver at each 3 axis (X, Y, Z), frequencies 5 – 500 Hz, 1.05 G for 1 hour |
Shock |
516.6 |
I, IV |
When packing, drop 1.22 m height for 6 surfaces, 8 corners, 12 edges (total 26 drops) |
Also meets equivalent MIL-STD-810-C, -D, -E and -F.
Ingress Protection Standard
Dust & Water |
IP54 (Dust-protection and water resistant) |
---|
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- BP-299, Battery pack
- BC-240, Desktop charger
- BC-242, AC adapter
- MB-124, Belt clip
- Antenna
HEADSETS
PTT/VOX CABLES
POWER SUPPLY CABLES
BELT CLIPS
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-F3002/IC-F4002 new version | 3.42MB |
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
Instruction manual | IC-F3000 series, IC-F4000 seires | |
Instructions | IC-F3000 series, IC-F4000 series | |
DOC (DECLARATION OF CONFORMITY) | IC-F3002 | |
DICHIARAZIONE DI CONFORMITA UE(ITALIANO) | IC-F3002 | |
DICHIARAZIONE DI CONFORMITA UE (ITALIANO) (5W) | IC-F4002 | |
DOC (DECLARATION OF CONFORMITY) (5W) | IC-F4002 |
Icom New IC-F3000 Series Promotion Video
Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.
Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |