Specifications
Charge Current | 840 mA |
---|---|
Power Supply Voltage | 12.0 ー 16.0 V DC |
Operating temperature range | +10℃~+40℃ (Li-ion) '+10℃~+35℃ (Ni-MH) |
Overcharge protect timer | 2.5 Hours (Ni-MH battery) 4.25 Hours (Li-Ion battery) |
Version List
Version Number | Version |
Supplied AC adapter |
Attachment | Battery pack |
---|---|---|---|---|
Ver 01 | OTH | No | AD-120 | BP-264 |
Ver 02 | USA | BC-157S (USA) | AD-120 | BP-264 |
Ver 03 | EUR | BC-157S (EUR) | AD-120 | BP-264 |
Ver 11 | OTH-01 | No | AD-121 | BP-265 |
Ver 12 | USA-01 | BC-157S (USA) | AD-121 | BP-265 |
Ver 13 | EUR-01 | BC-157S (EUR) | AD-121 | BP-265 |
Ver 21 | OTH-02 | No | AD-122 | BP-232H / BP-232WP |
Ver 22 | USA-02 | BC-157S (USA) | AD-122 | BP-232H / BP-232WP |
Ver 23 | EUR-02 | BC-157S (EUR) | AD-122 | BP-232H / BP-232WP |
Ver 26 | OTH-03 | No | AD-124 | BP-275 |
Ver 27 | USA-03 | BC-157S (USA) | AD-124 | BP-275 |
Ver 28 | EUR-03 | BC-157S (EUR) | AD-124 | BP-275 |
Ver 31 | OTH-04 | No | AD-129 | BP-245H (IC-M73) |
Ver 32 | USA-04 | BC-157S (USA) | AD-129 | BP-245H (IC-M73) |
Ver 33 | EUR-04 | BC-157S (EUR) | AD-129 | BP-245H (IC-M73) |
Ver 36 | OTH-07 | No | AD-128 | BP-227 |
Ver 37 | USA-12 | BC-157S (USA) | AD-128 | BP-227 |
Ver 38 | EUR-07 | BC-157S (EUR) | AD-128 | BP-227 |


Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |