Descriptions
・Pole mount passive antenna.
・Connect to the IC-SAT100 with the OPC-2113 (10 m, 32.8 ft) or user supplied coaxial cable.
Specifications
Frequency range | 1575.42 – 1626.48 MHz |
---|---|
Dimensions | 160.0 (dia) × 80.5 (H) mm, 6.3 (dia)× 3.2 (H) inch |
Weight | 350 g; 12.3 oz |
Operating temperature range | –30˚C to +60˚C, –22˚F ~ +140˚F |
VSWR | Maximum 1.7 |
IP rating | IP66 |
Optional Accessory

OPC-2113
Coaxial cable (10 m, 32.8 ft)
Suggested Main Antenna Cables
Use optional OPC-2113 or user supplied coaxial cable to meet Iridium® performance requirements, and comply with FCC regulations.
Cable loss requirement from the IC-SAT100 to the AH-38 | Less than 3.4 dB loss at 1500 MHz |
---|
Reference Cable | Diameter | Cable Length |
---|---|---|
Times Microwave Systems | - | |
LMR 240 | 6.10 mm, 0.240 inch | 9 m, 29.5 ft |
LMR 300 | 7.62 mm, 0.300 inch | 11 m, 36.1 ft |
LMR 400 | 10.29 mm, 0.405 inch | 17 m, 55.8 ft |
LMR 500 | 12.70 mm, 0.500 inch | 22 m, 72.2 ft |
LMR 600 | 14.99 mm, 0.590 inch | 27 m, 88.6 ft |
LMR 900 | 22.10 mm, 0.870 inch | 45 m, 147.6 ft |
Above cable lengths are for your reference which are calculated by the target cable loss at 1500 MHz.
Satellite PTT
Instruction Manual / Guides
Name | Model Name | Note |
---|---|---|
INSTRUCTIONS (ENG/GER/ESP/FRA/ITA) | AH-38 |


Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |
IPx4 | Protected against water splashed against the equipment from any direction |