Discontinued ProductNote: The contents of this page is as of the time it was created.
VHF AND UHF DIGTAL TRANSCIVERS
IC-F3360D
IC-F4360D
Series
Ready for NXDN™ Type-C Trunking with Superior Waterproof Protection
- VHF/10-keypad/IDAS DIGTAL IC-F3360DT
- VHF/Simple key/IDAS DIGTAL IC-F3360DS
- UHF/10-keypad/IDAS DIGTAL IC-F4360DT
- UHF/Simple key/IDAS DIGTAL IC-F4360DS
Type-C Trunking Compatible
The IC-F3360D series provides NXDN™ Type-C trunking and NXDN™ conventional systems.
- Paging call
- Broadcast call
- All call
- Group call
- Individual call
- Status call
- Text message
- Emergency call
- Stun, Kill and Revive (RX)
- Radio check (RX)
- Over-the-air alias
- GPS
- 15-bit digital scrambler
- RAN
- Mixed mode operation (Conventional system)
Menu-Driven User Interface
The menu-driven user interface provides easy and intuitive operation. The functions can be toggled with the left and right [P2] and [P3] buttons and allow you to perform various operations and settings.


Built-in GPS Receiver
Your current position data can be attached to a voice or data (status or emergency signal) transmission and can be sent to dispatch stations.
Man Down & Lone Worker
The man down function sends an emergency signal if left in a horizontal position. The lone worker function detects if the transceiver is not operated or not moved for a preset period.
Transparent Data
When IC-F3360D series is connected to a PC or other external equipment, the transparent data function allows data communication in a digital mode.
IP67 Dust-Tight & Waterproof
The IC-F3360D series provides rugged protection against dust and water. The transceiver can with stand 1m depth of water for 30 minutes.
800mW (typ.) Audio Output
The built-in BTL amplifier doubles the audio output power and the large 40mm speaker delivers loud 800mW (typ.) audio to receive all calls under noisy environments.
Other Features
- 512 memory channels with 128 zones
- CTCSS/DTCS/DTMF encoder/decoder*
- MDC 1200 PTT ID transmission*
- Inversion voice scrambler*
- Audio compander*
(* = Analog mode only)
General
IC-F3360DT/DS | IC-F4360DT/DS | |||
---|---|---|---|---|
Frequency coverage | 136–174MHz | 400–470MHz | ||
Number of channels | 512 channels/128 zones | |||
Type of emission | 8K50F3E, 8K30F1E/F1D, 4K00F1E/F1D | |||
Channel spacing | 15/12.5/6.25kHz | |||
Power supply requirement | 7.5V DC nominal | |||
Current drain (approx.) |
Tx High (at 5W) | 1.5A | 1.8A | |
Rx | Rated output |
550mA |
||
Standby |
140mA |
|||
Antenna impedance | 50Ω | |||
Operating temperature range | −30°C to +60°C; −22°F to +140°F (Radio specifications) |
|||
Dimensions (W×H×D) (Projections not included) |
53.5×142.7×39.5 mm; 2.11×5.62×1.56 in (With BP-232WP) |
|||
Weight (approx.) | 400g; 14.1oz (With BP-232WP, MB-94R & FA-SC57U) |
Transmitter
IC-F3360DT/DS | IC-F4360DT/DS | |||
---|---|---|---|---|
Output power (at 7.5V DC) | 5W, 1W (Hi, Low) | |||
Max. frequency deviation | ±2.5kHz (Narrow) | |||
Frequency stability | ±1.0ppm | |||
Spurious emissions | 75dB typ. | |||
FM Hum and noise | 50dB typ. (Narrow) | 45dB typ. (Narrow) | ||
Audio harmonic distortion | 1.5% typ. (AF 1kHz 40% deviation) | |||
FSK error | 1% typ. (Digital 6.25/12.5kHz) | |||
Ext. microphone connector | 14-pin multi-connector/2.2kΩ |
Receiver
IC-F3360DT/DS | IC-F4360DT/DS | |||
---|---|---|---|---|
Sensitivity | Analog |
0.24μV typ. (12 dB SINAD) |
||
Digital |
−8.0dBμV emf typ. (0.20 μV typ.) (5% BER) |
|||
Adjacent channel selectivity | 68/67/59dB typ. (Narrow/D 12.5kHz/D 6.25kHz) | |||
Spurious response rejection | 80dB typ. | |||
Intermodulation rejection | 75/70/70dB typ. (Narrow/D 12.5kHz/D 6.25kHz) | |||
Hum and noise | 50dB typ. (Narrow) | 48dB typ. (Narrow) | ||
Audio output power (at 5% distortion) |
800mW typ. (Internal SP, 12Ω load) 1000mW typ. (External SP, 8Ω load) |
|||
Ext. speaker connector | 14-pin multi-connector/8Ω |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 G Method, Proc. |
---|---|
Low Pressure Storage |
500.5 I |
Low Pressure Operation |
500.5 II |
High Temperature Storage |
501.5 I |
High Temperature Operation |
501.5 II |
Low Temperature Storage |
502.5 I |
Low Temperature Operation |
502.5 II |
Temperature Shock |
503.5 I-C |
Solar Radiation |
505.5 I |
Rain Blowing |
506.5 I |
Rain Drip |
506.5 III |
Humidity Induced |
507.5 II |
Salt Fog |
509.5 |
Dust Blowing |
510.5 I |
Immersion |
512.5 I |
Vibration |
514.6 I |
Shock Functional |
516.6 I |
Shock Transit Drop |
516.6 IV |
Also meets equivalent MIL-STD-810 -C, -D, -E and -F.
Ingress Protection Standards (IC-F3360D/F4360D, BP-232WP and HM-184) | |
---|---|
Dust & Water |
IP67 (Dust-tight and waterproof protection) |
All stated specifications are subject to change without notice or obligation.
Supplied Accessories
- Battery pack, BP-232WP
- Belt clip, MB-94R
- Antenna
Note that a Battery charger must be purchased separatelly.
MICROPHONES
HEADSETS
PTT/VOX CABLES
CHARGERS
AC ADAPTERS
POWER SUPPLY CABLES
MOUNTING BRACKETS
BELT CLIPS
BELT HANGERS
ANTENNAS
ADAPTERS
Catalogs / Brochures
Brochures Name | Size |
---|---|
IC-F3360D/IC-F4360D Digital Series | 404KB |
IDAS™ Solutions | 2.43MB |



Ingress Protection (IP) Code
Ingress Protection (IP) ratings define the level of protection provided by enclosures to prevent the ingress of foreign objects (dust) and liquid into the electrical equipment.
International Standard IEC 60529 outlines an international classification system that describes the sealing characteristics of electrical equipment.
The classification system uses the “IP” code, or “Ingress Protection” code, to define the level of seal.
An IP number contains two numbers (i.e. IP67) in most instances which relate to the level of protection provided by an enclosure or housing.
Either number may be shown as “X” (i.e. IPX6 / IP7X) to indicate the “X” part is not tested.


Degrees of Solid Particle Protection – 1st Digit
IP6x | No ingress of dust; complete protection against contact. (Dust tight) |
---|---|
IP5x | Protected from the amount of dust that would interfere with normal operation. (Dust protected) |
Degrees of Liquid Ingress Protection – 2nd Digit
IPx8 | Protected against continuous immersion in water. Depth and duration specified by model. |
---|---|
IPx7 | Protected against temporary immersion in water for 1 m (3.3 ft) for 30 minutes |
IPx6 | Protected against water projected by powerful jets from any direction. 100 L per minute by a powerful jets (12.5 mm) for 3 minutes. |
IPx5 | Protected against water projected by jets from any direction. 12.5 L per minute by a nozzle (6.3 mm) for 3 minutes. |